All Products
Compatible Optics
Services
Support
About Us
Resources
OEM-coded optical modules for major platforms
Curated album pages for cages and copper optics
Mind your business with a variety of trusted payment options.
Use order number or tracking number to check shipping status.
Get your quote fast and offer you more professional service.
Help manage your budget & expenditure better.
Free samples support, achieve your test results efficiently.
Professional team support and service, to solve your problems in time.
Ask us whatever you care, we will help you 24/7.
Get your quote fast and offer you more professional service.
Meet us and know our mission, belief, service and more.
Find our locations and get connected with us closely.
Quality management, testing, compatibility and global compliance.
Find out the latest news and events around l-p.com
Deep dive into technical guides, industry standards, and SFP compatibility insights.
Detailed product benchmarks and side-by-side comparisons to help you choose the right module.
Explore real-world connectivity solutions for data centers, enterprises, and telecom networks.
Essential tips on choosing data rates, transmission distances, and connector types.
New Customer? Create an account
The 10G-SFPP-ZRD-1530.33 serves as a 10G SFP+ DWDM solution configured for the 1530.33nm (C59) channel on the standard 100GHz ITU grid. Built with a cooled EML laser and high-sensitivity APD photodiode, it reliably spans up to 80km over single-mode fiber and provides real-time digital optical monitoring (DOM) for proactive network management.
| Brocade Part Number | 10G-SFPP-ZRD-1530.33 | Vendor Name | LINK-PP |
| Form Factor | SFP+ | Max Data Rate | 10.7Gbps |
| Wavelength | 1530.33nm | Max Cable Distance | 80km |
| Connector | Duplex LC | Media | SMF |
| Transmitter Type | EML | Receiver Type | APD |
| TX Power | -1 to +5dBm | RX Power | -23 to -6dBm |
| Receiver Sensitivity | -23dBm | DDM/DOM | Supported |
| Operating Temperature Range | 0 to 70°C | Protocols | 10GBASE-ZR/ZW, SDH STM64, SFF-8431, SFF-8472 |
Brocade 10G-SFPP-ZRD-1530.33 Compatible LINK-PP provides reliable 10Gbps DWDM connectivity tailored for long-distance single-mode fiber deployments. Key highlights include a 1530.33nm center wavelength, 80km link span, standard duplex LC interface, and integrated real-time DOM diagnostics.
This transceiver features a hot-pluggable SFP+ footprint for quick installation and maintenance without powering down host systems. Built in strict compliance with the SFP+ MSA, it ensures broad mechanical and electrical compatibility across diverse networking hardware.
A dedicated 10Gbps data rate delivers dependable bandwidth for high-traffic metro core routing and switching backbones. It provides stable throughput to meet the continuous aggregation demands of enterprise and campus network backhauls.
Dense Wavelength Division Multiplexing enables multiple data channels to run simultaneously over a single optical strand. This technology maximizes existing fiber infrastructure capacity while significantly lowering cabling expansion costs.
Channel C59 operation at 1530.33nm aligns precisely with the standard 100GHz ITU-T wavelength grid. A cooled EML transmitter maintains tight spectral stability within the low-loss C-band transmission window.
Long-distance capability allows point-to-point single-mode fiber spans of up to 80km without intermediate optical amplification. An integrated high-sensitivity APD receiver maintains link integrity over extended spans.
The industry-standard duplex LC optical connector ensures seamless mating with common patch cords and patch panels. Robust latching mechanics provide secure physical retention and minimal insertion loss during continuous operation.
Internal diagnostic circuitry fully supports SFF-8472 digital optical monitoring functions. Network operators can track real-time optical power, bias current, operating temperature, and supply voltage directly through network management interfaces.
Brocade 10G-SFPP-ZRD-1530.33 Compatible LINK-PP DWDM SFP+ module adheres to rigorous international quality and regulatory frameworks to guarantee safe, reliable operation. The module fully complies with global standards including ISO 9001, CE, RoHS, and FCC certifications.
Every 10G DWDM optical module undergoes strict testing to verify optical spectral stability and bit error rate performance. Comprehensive signal integrity checks ensure each module operates reliably across its entire service life.
These certifications show that the transceiver is built according to strict international regulations. Enterprise and carrier clients can safely deploy these modules knowing they meet proven quality standards.
Comprehensive host interoperability validation ensures smooth integration with mainstream switches, routers, and transport gear. Correct EEPROM encoding enables seamless plug-and-play identification without triggering port warnings or protocol errors.
Every 10G-SFPP-ZRD-1530.33 DWDM 10G SFP+ optical transceiver undergoes comprehensive performance inspections to ensure optimal transmission quality and hardware reliability. To learn more about our detailed validation procedures, visit the LINK-PP Test Support Center.
Verify center wavelength accuracy and spectral purity on ITU channels.
Evaluate optical signal clarity and transmitter jitter performance boundaries.
Confirm error-free data transmission across extended fiber link distances.
Check stable transceiver operation across varying commercial thermal conditions.
LINK-PP provides secure packaging and reliable shipping methods to protect optical transceiver modules during transit. Standardized logistics procedures ensure every order arrives safely and promptly at worldwide customer locations.
Prevent electrostatic damage using specialized antistatic packaging for optical modules.
Protect optical modules against physical impact and vibrations during transportation.
Accelerate order fulfillment to ensure swift dispatch from warehouse facilities.
Deliver shipments worldwide through reliable international express and freight carriers.
The 10G-SFPP-ZRD-1530.33 DWDM module provides hot-swappable installation by sliding into standard SFP+ cages and mating with duplex LC patch cables. Properly aligned with DWDM optical multiplexers, it establishes secure 80km point-to-point links to optimize fiber capacity and data throughput throughout metro core networks.
LINK-PP offers end-to-end technical support, from pre-sales consultation to post-deployment assistance, ensuring smooth integration and reliable network performance.
Professional guidance to help you select the optimal 10G-SFPP-ZRD-1530.33 module for your network design and application needs.
Validated compatibility with LINK-PP switches and other mainstream networking platforms for seamless deployment.
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
LINK-PP provides after-sales support for the smooth deployment and reliable operation of the optical modules.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
![]() LS-CW5510-10I
| ![]() LS-DW4610-40I
| ![]() LS-DW5910-80I
| ![]() LS-DW6110-80I
| ![]() LS-DW6010-80I
|
|---|
Compatible | Brocade | Brocade | Brocade | Brocade | Brocade | Brocade |
Data Rate (Max) | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps |
Wavelength | 1530.33nm | 1550nm | 1540.55nm | 1530.33nm | 1528.77nm | 1529.55nm |
Connector | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC |
Cable Distance (Max) | 80km | 10km | 40km | 80km | 80km | 80km |
Cable Type | SMF | SMF | SMF | SMF | SMF | SMF |
TX Power | -1 to +5dBm | -5 to +1dBm | -1 to +2dBm | -1 to +5dBm | -1 to +5dBm | -1 to +5dBm |
Receiver Sensitivity | -23dBm | -16 to -1dBm | -16 to -1dBm | -23dBm | -23dBm | -23dBm |
Operating Temperature | 0 to 70°C | -40 to 85°C | -40 to 85°C | -40 to 85°C | -40 to 85°C | -40 to 85°C |
Vendor Name | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP |
Brocade Part Number | 10G-SFPP-ZRD-1530.33 | CW-SFP10G10-55-I | 10G-SFPP-ZRD-1540.56-I | 10G-SFPP-ZRD-1530.33-I | 10G-SFPP-ZRD-1528.77-I | 10G-SFPP-ZRD-1529.55-I |
Temperature | Commercial | Industrial | Industrial | Industrial | Industrial | Industrial |
Form Factor | SFP+ | SFP+ | SFP+ | SFP+ | SFP+ | SFP+ |
Transmitter Type | EML | DFB | EML | EML | EML | EML |
Receiver Type | APD | PIN | PIN | APD | APD | APD |
DDM/DOM | Supported | Supported | Supported | Supported | Supported | Supported |
Protocols | 10GBASE-ZR/ZW, SDH STM64, SFF-8431, SFF-8472 | SFP+ MSA, SFF-8472, ITU-T G.652 | SFP+ MSA, SFF-8431, SFF 8472, 10GBASE-ER/EW, SDH STM64 | 10GBASE-ZR/ZW, SDH STM64, SFF-8431, SFF-8472 | 10GBASE-ZR/ZW, SDH STM64, SFF-8431, SFF-8472 | 10GBASE-ZR/ZW, SDH STM64, SFF-8431, SFF-8472 |
| Pictures | ID# | Description | Price | Stock | Add to Cart |
Q: What type of fiber patch cable should I choose for this DWDM transceiver? By H***s
A: You need a standard 9/125 single-mode fiber patch cable fitted with duplex LC connectors. Multimode fiber is not compatible and will cause severe signal loss over DWDM wavelengths. By admin
Q: What are the recommended warehouse storage conditions for spare inventory? By J***a
A: Spare modules can be stored safely in dry, non-condensing environments between -40°C and 85°C. Keep them in their original anti-static blister packaging to protect the optical modules. By admin
Q: Can I use this SFP+ module on an adjacent 100GHz DWDM channel port like C58 or C60? By S***n
A: No, this is a fixed-wavelength module tuned specifically to 1530.33nm. It must be connected to a matching C59 channel port to pass through passive DWDM multiplexers without severe signal attenuation. By admin
Q: What are the symptoms of an optical overload on this transceiver's APD receiver? By K***s
A: An overloaded APD typically generates high bit error rates, intermittent link drops, or a sudden loss of carrier signal. In severe cases of persistent high optical power, the receiver circuit can suffer permanent hardware damage. By admin
Q: Can tight cable bends in the rack cable manager cause link drops on this DWDM SFP+ module? By D***d
A: Yes, sharp bends introduce macro-bending optical losses that consume your 22dB link margin. Maintaining proper fiber bend radius ensures optimal optical signal delivery over the entire span. By admin
United States
Carrier
CostDelivery TimeTracking
Company
CostTime
To Be Negotiated Available