All Products
Compatible Optics
Services
Support
About Us
Resources
OEM-coded optical modules for major platforms
Curated album pages for cages and copper optics
Mind your business with a variety of trusted payment options.
Use order number or tracking number to check shipping status.
Get your quote fast and offer you more professional service.
Help manage your budget & expenditure better.
Free samples support, achieve your test results efficiently.
Professional team support and service, to solve your problems in time.
Ask us whatever you care, we will help you 24/7.
Get your quote fast and offer you more professional service.
Meet us and know our mission, belief, service and more.
Find our locations and get connected with us closely.
Quality management, testing, compatibility and global compliance.
Find out the latest news and events around l-p.com
Deep dive into technical guides, industry standards, and SFP compatibility insights.
Detailed product benchmarks and side-by-side comparisons to help you choose the right module.
Explore real-world connectivity solutions for data centers, enterprises, and telecom networks.
Essential tips on choosing data rates, transmission distances, and connector types.
New Customer? Create an account
The 10G-SFPP-ZRD-1531.12 operates as a 10G DWDM SFP+ module centered at the 1531.12nm (C58) ITU 100GHz grid, leveraging an integrated cooled EML laser and APD receiver to achieve transmission distances up to 80km over SMF. It features hot-pluggable electrical connectivity alongside real-time digital diagnostic monitoring (DDM) for accurate network status analysis.
| Brocade Part Number | 10G-SFPP-ZRD-1531.12 | Vendor Name | LINK-PP |
| Form Factor | SFP+ | Max Data Rate | 10.7Gbps |
| Wavelength | 1531.12nm | Max Cable Distance | 80km |
| Connector | Duplex LC | Media | SMF |
| Transmitter Type | EML | Receiver Type | APD |
| TX Power | -1 to +5dBm | RX Power | -23 to -6dBm |
| Receiver Sensitivity | -23dBm | DDM/DOM | Supported |
| Operating Temperature Range | 0 to 70°C | Protocols | 10GBASE-ZR/ZW, SDH STM64, SFF-8431, SFF-8472 |
Brocade 10G-SFPP-ZRD-1531.12 Compatible LINK-PP combines 10Gbps transmission speed with dense wavelength division multiplexing technology to support single-mode fiber links up to 80km. Engineered with an industry-standard duplex LC interface and real-time digital monitoring, it provides a reliable, long-reach optical solution for commercial network environments.
Designed with a hot-pluggable SFP+ footprint, this optical transceiver enables quick field replacements without interrupting host network services. It strictly follows the SFP+ MSA standard to ensure seamless mechanical fit and electrical interoperability across diverse networking platforms.
The module delivers a steady 10Gbps data rate to meet the bandwidth demands of modern carrier access rings and metro distribution points. Its robust throughput helps service providers aggregate multiple local traffic streams efficiently into regional transport hubs.
Dense Wavelength Division Multiplexing enables multiple independent data channels to run concurrently over a single physical fiber pair. This capability significantly increases total bandwidth capacity without requiring expensive new cable installations.
Channel 58 operates on a fixed optical wavelength of 1531.12nm in accordance with the 100GHz ITU-T C-band grid. This precise spectral alignment minimizes channel crosstalk when multiplexed with neighboring DWDM frequencies.
An integrated cooled EML transmitter and sensitive APD receiver enable reliable optical reach across spans up to 80km on single-mode fiber. This extended distance capability eliminates the immediate need for intermediate optical amplifiers in long-haul routes.
The industry-standard duplex LC optical connector ensures low insertion loss and secure patch cord mating. Its compact dual-fiber design fits high-density switch front panels while maintaining dependable physical connectivity.
Digital diagnostic functions compatible with SFF-8472 give network administrators immediate visibility into critical parameters such as optical power, operating temperature, and bias current. These diagnostic metrics help engineers detect link degradation early and streamline routine troubleshooting.
Brocade 10G-SFPP-ZRD-1531.12 Compatible LINK-PP SFP+ DWDM module adheres to strict manufacturing and quality controls governed by ISO 9001 standards. The transceiver also holds CE, RoHS, and FCC certifications, validating its safety, environmental compliance, and electromagnetic reliability.
Every 10G DWDM SFP+ module undergoes rigorous factory inspection, including optical eye-pattern verification, bit error rate analysis, and thermal stress cycles. These comprehensive testing procedures ensure consistent signal stability and reliable operation in long-haul transmission links.
This module meets globally recognized industrial standards for environmental safety, hazardous material restrictions, and electromagnetic emissions. These verified credentials assure network operators that the module is safe to deploy across enterprise and telecom infrastructures.
Strict cross-platform verification on mainstream networking gear guarantees flawless integration with your host hardware. This testing process eliminates port configuration errors and ensures continuous, dependable link performance.
Every 10G-SFPP-ZRD-1531.12 10G DWDM SFP+ optical module undergoes comprehensive factory evaluations to guarantee optimal signal integrity and long-distance transmission stability. To explore our validation procedures in detail, visit the LINK-PP Test Support Center.
Inspect optical spectrum alignment to prevent DWDM channel frequency drift.
Evaluate optical signal quality and transmitter jitter performance under load.
Measure data transmission accuracy across extended single-mode fiber links reliably.
Assess thermal stability and operational endurance across standard commercial ranges.
Each 10G-SFPP-ZRD-1531.12 DWDM 10G SFP+ optical transceiver is packaged and handled under strict quality standards to ensure safe transit. We coordinate with reliable carriers to deliver your orders quickly and securely to destinations worldwide.
Utilize electrostatic shielding packs to prevent static damage during transit.
Employ reinforced outer cartons to safeguard internal optical components securely.
Accelerate warehouse handling workflows to ensure rapid order dispatch.
Partner with trusted international couriers to provide prompt worldwide shipping.
Simply insert the 10G-SFPP-ZRD-1531.12 10G DWDM module into an SFP+ port, connect clean duplex LC single-mode fiber, and verify DWDM C58 channel alignment. In metro-access aggregation deployments, it aggregates distributed 10G traffic into core transport rings across 80km spans without requiring intermediate amplification.
LINK-PP offers end-to-end technical support, from pre-sales consultation to post-deployment assistance, ensuring smooth integration and reliable network performance.
Professional guidance to help you select the optimal 10G-SFPP-ZRD-1531.12 module for your network design and application needs.
Validated compatibility with LINK-PP switches and other mainstream networking platforms for seamless deployment.
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
LINK-PP provides after-sales support for the smooth deployment and reliable operation of the optical modules.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
![]() LS-CW5510-10I
| ![]() LS-DW4610-40I
| ![]() LS-DW5810-80I
| ![]() LS-DW6110-80I
| ![]() LS-DW6010-80I
|
|---|
Compatible | Brocade | Brocade | Brocade | Brocade | Brocade | Brocade |
Data Rate (Max) | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps |
Wavelength | 1531.12nm | 1550nm | 1540.55nm | 1531.12nm | 1528.77nm | 1529.55nm |
Connector | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC |
Cable Distance (Max) | 80km | 10km | 40km | 80km | 80km | 80km |
Cable Type | SMF | SMF | SMF | SMF | SMF | SMF |
TX Power | -1 to +5dBm | -5 to +1dBm | -1 to +2dBm | -1 to +5dBm | -1 to +5dBm | -1 to +5dBm |
Receiver Sensitivity | -23dBm | -16 to -1dBm | -16 to -1dBm | -23dBm | -23dBm | -23dBm |
Operating Temperature | 0 to 70°C | -40 to 85°C | -40 to 85°C | -40 to 85°C | -40 to 85°C | -40 to 85°C |
Vendor Name | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP |
Brocade Part Number | 10G-SFPP-ZRD-1531.12 | CW-SFP10G10-55-I | 10G-SFPP-ZRD-1540.56-I | 10G-SFPP-ZRD-1531.12-I | 10G-SFPP-ZRD-1528.77-I | 10G-SFPP-ZRD-1529.55-I |
Temperature | Commercial | Industrial | Industrial | Industrial | Industrial | Industrial |
Form Factor | SFP+ | SFP+ | SFP+ | SFP+ | SFP+ | SFP+ |
Transmitter Type | EML | DFB | EML | EML | EML | EML |
Receiver Type | APD | PIN | PIN | APD | APD | APD |
DDM/DOM | Supported | Supported | Supported | Supported | Supported | Supported |
Protocols | 10GBASE-ZR/ZW, SDH STM64, SFF-8431, SFF-8472 | SFP+ MSA, SFF-8472, ITU-T G.652 | SFP+ MSA, SFF-8431, SFF 8472, 10GBASE-ER/EW, SDH STM64 | 10GBASE-ZR/ZW, SDH STM64, SFF-8431, SFF-8472 | 10GBASE-ZR/ZW, SDH STM64, SFF-8431, SFF-8472 | 10GBASE-ZR/ZW, SDH STM64, SFF-8431, SFF-8472 |
| Pictures | ID# | Description | Price | Stock | Add to Cart |
Q: Does this DWDM transceiver require manual wavelength tuning before installation? By J***s
A: No, this is a fixed-wavelength transceiver pre-locked to the ITU-T C58 grid at 1531.12nm straight from the factory. You can plug it directly into the corresponding MUX port without any software calibration. By admin
Q: Can I mix this 1531.12nm channel with other DWDM wavelengths over a single pair of fiber? By M***r
A: Yes, that is the main purpose of passive DWDM Mux and Demux equipment. You can multiplex this C58 channel alongside other 100GHz ITU-grid optics on one single-mode fiber pair. By admin
Q: Can I clean the optical interface with a standard 1.25mm fiber cleaning pen? By M***n
A: Yes, the transceiver uses a standard duplex LC interface that fits any standard 1.25mm optical cleaning tool. Regular dry cleaning of the optical end-face before patching is strongly recommended to protect the APD. By admin
United States
Carrier
CostDelivery TimeTracking
Company
CostTime
To Be Negotiated Available