All Products
Compatibility
Services
Support
About Us
Resources
Device-platform coding for switches, NICs and routers — not OEM-branded parts.
All optics brands Full brand directory and popular OEM part numbers.Form-factor categories and OEM cage brand hubs with Compatible P/N catalog.
Shop Compatible cages Filter Compatible P/Ns by brand and attributes.Alternatives to OEM P/Ns — not an OEM authorization claim.
Port / style categories and Magjack brand hubs with Compatible P/N alternatives.
Shop Compatible Magjacks Filter Compatible P/Ns by brand and attributes.Alternatives to OEM P/Ns — not an OEM authorization claim.
LAN magnetics categories and brand hubs with Compatible P/N alternatives.
Shop Compatible LAN Filter Compatible P/Ns by brand and attributes.Alternatives to OEM P/Ns — not an OEM authorization claim.
Mind your business with a variety of trusted payment options.
Use order number or tracking number to check shipping status.
Get your quote fast and offer you more professional service.
Help manage your budget & expenditure better.
Free samples support, achieve your test results efficiently.
Professional team support and service, to solve your problems in time.
Ask us whatever you care, we will help you 24/7.
Get your quote fast and offer you more professional service.
Meet us and know our mission, belief, service and more.
Find our locations and get connected with us closely.
Quality management, testing, compatibility and global compliance.
Find out the latest news and events around l-p.com
Deep dive into technical guides, industry standards, and SFP compatibility insights.
Detailed product benchmarks and side-by-side comparisons to help you choose the right module.
Explore real-world connectivity solutions for data centers, enterprises, and telecom networks.
Essential tips on choosing data rates, transmission distances, and connector types.
New Customer? Create an account
Need a qty beyond these tiers, or to negotiate price?
The LINK-PP LF5-MM851G-02IDS is a 1.25Gbps 2x5 SFF transceiver pairing an 850nm VCSEL transmitter with a PIN photodiode receiver. It reaches 2km over 50/125µm multimode fiber and 300m over 62.5/125µm, runs from a single 3.3V rail at 300mA maximum, and operates from -40°C to +85°C through a duplex LC receptacle with LVPECL data I/O.
| LINK-PP Part Number | LF5-MM851G-02IDS | Vendor Name | LINK-PP |
| Form Factor | SFF | Max Data Rate | 1.25Gbps |
| Wavelength | 850nm | Max Cable Distance | 2km |
| Connector | Duplex LC | Media | MMF |
| Transmitter Type | VCSEL | Receiver Type | PIN |
| Power Supply | 3.3V | Operating Temperature Range | -40 to 85°C |
Every element of the LF5-MM851G-02IDS is chosen for dense, long-life multimode links: a 2x5 through-hole footprint, 1.25Gbps LVPECL signaling, an 850nm VCSEL, 2km reach, duplex LC optics and an industrial temperature range that keeps Gigabit Ethernet and Fiber Channel ports stable in cabinets and outdoor enclosures.
The LF5-MM851G-02IDS follows the industry-standard 2x5 SFF outline with through-hole pins on a 2.54mm grid. Its metal shell shields the optics, the case is isolated from circuit ground, and the solder-down design removes plug-in contact wear on vibration-prone boards.
The module transmits and receives at 1.25Gbps over LVPECL differential pairs, matching 1000BASE-SX Gigabit Ethernet and 1.063Gbps Fiber Channel. AC-coupled inputs and a 100Ω differential impedance keep rise times clean, so switches, media converters and NICs lock without retiming.
An 850nm VCSEL sits at the low-loss window of multimode fiber, where 50/125µm OM3 and OM4 cable carries the signal with minimal attenuation. Centre wavelength stays within 850nm ±50nm, and -9dBm to -3dBm output power keeps coupling stable.
Transmission reaches 2km over 50/125µm multimode fiber and 300m over legacy 62.5/125µm cable. Receiver sensitivity of -17dBm, 8.2dB minimum extinction ratio and 0.5dB SD hysteresis give the link margin to survive dirty connectors and aged patch cords.
A duplex LC receptacle accepts standard patch cords and halves the connector footprint of SC designs. The metallized housing and filtered pinout suppress emissions to FCC Part 15 Class B and EN 55022 Class B limits, easing chassis-level EMC approval.
LINK-PP tests every LF5-MM851G-02IDS against optical, electrical and safety standards before shipment, and the module carries the compliance records that network equipment makers need for their own regulatory filings.
Each unit is 100% tested for output power, sensitivity and eye margin using 2^23-1 PRBS patterns at 1250Mbps. Lot traceability covers VCSEL, PIN and PCB batches.
Compliance records include RoHS 2.0 (2011/65/EU), UL/cUL EN60950-1 under file E317337, TÜV certificate 50135086, Class 1 laser status to IEC 60825, plus ESD Class 1C above 1000V.
Pin assignments, land patterns and LVPECL levels follow the 2x5 SFF multi-source agreement, and the optical eye meets IEEE 802.3z. Drop-in replacement keeps existing board layouts and host firmware untouched.
Four bench tests screen every LF5-MM851G-02IDS before it leaves the line, covering spectrum, eye quality, error rate and temperature extremes.
Centre wavelength, RMS spectral width and side-mode suppression are measured to confirm 850nm VCSEL output.
Filtered eye diagrams are captured at 1250Mbps and compared against the IEEE 802.3z mask.
PRBS 2^23-1 traffic confirms BER below 1E-12 at rated sensitivity over 2km of fiber.
Chambers sweep -40°C to +85°C while monitoring power, sensitivity and signal detect thresholds.
Orders ship in ESD-safe trays with individual optical port caps, packed for air and sea freight and dispatched within the quoted lead time.
Each module sits in a shielded tray with dust caps fitted.
Foam-lined cartons absorb impact and keep pins straight in transit.
Stock items leave the warehouse within 24 to 48 hours.
Express and air freight reach North America, Europe and Asia.
Installing the LINK-PP LF5-MM851G-02IDS requires standard wave soldering onto the host PCB. Align the 2x5 pins with the board pads, solder them securely, then connect the duplex LC patch cord to bring up a high-speed 1.25G fiber link.
LINK-PP provides professional technical support, including pre-sales consultation, compatibility verification, and post-deployment troubleshooting to ensure smooth network operation.
Professional technical guidance to help customers select the most suitable LF5-MM851G-02IDS modules based on network architecture and application requirements.
Compatibility checks and validation to ensure seamless operation with Cisco switches and other supported networking platforms.
Step-by-step support for installation, configuration, and initial deployment to ensure stable and correct operation.
Ongoing technical support throughout the product lifecycle to ensure reliable performance in enterprise and carrier-grade networks.
LINK-PP provides after-sales support for the smooth deployment and reliable operation of the optical modules.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
![]() Current Model LF5-MM851G-02IDS |
|---|
Compatible | LINK-PP | LINK-PP | LINK-PP |
Data Rate (Max) | 1.25Gbps | 1.25Gbps | 1.25Gbps |
Wavelength | 850nm | 850nm | 1310nm |
Connector | Duplex LC | Duplex LC | Duplex LC |
Cable Distance (Max) | 2km | 550m | 20km |
Cable Type | MMF | MMF | SMF |
Operating Temperature | -40 to 85°C | -40 to 85°C | -40 to 85°C |
Fiber Type | Multimode | Multimode | SMF |
Optical Interface | Duplex LC | Duplex LC | Duplex LC |
Form Factor | SFF | SFF | SFF |
Transmitter Type | VCSEL | VCSEL | FP |
Receiver Type | PIN | ||
Power Supply | 3.3V | 3.3V | 3.3V |
| Pictures | ID# | Description | Price | Stock | Add to Cart |
22 Reviews
United States
Carrier
Cost·Delivery Time·Tracking
Company
Cost·Time
Free Shipping To Be Negotiated Available