All Products
Compatible Optics
Services
Support
About Us
Resources
OEM-coded optical modules for major platforms
Curated album pages for cages and copper optics
Mind your business with a variety of trusted payment options.
Use order number or tracking number to check shipping status.
Get your quote fast and offer you more professional service.
Help manage your budget & expenditure better.
Free samples support, achieve your test results efficiently.
Professional team support and service, to solve your problems in time.
Ask us whatever you care, we will help you 24/7.
Get your quote fast and offer you more professional service.
Meet us and know our mission, belief, service and more.
Find our locations and get connected with us closely.
Quality management, testing, compatibility and global compliance.
Find out the latest news and events around l-p.com
Deep dive into technical guides, industry standards, and SFP compatibility insights.
Detailed product benchmarks and side-by-side comparisons to help you choose the right module.
Explore real-world connectivity solutions for data centers, enterprises, and telecom networks.
Essential tips on choosing data rates, transmission distances, and connector types.
New Customer? Create an account
LS-DW2910-40C operates as a 10G SFP+ DWDM transceiver module configured for 1554.13nm (C29) with 100GHz channel spacing. Built with a cooled EML laser and PIN photodiode architecture, the module achieves up to 40km SMF transmission and incorporates real-time digital optical monitoring per SFF-8472 standards.
| LINK-PP Part Number | LS-DW2910-40C | Vendor Name | LINK-PP |
| Form Factor | SFP+ | Max Data Rate | 10.7Gbps |
| Wavelength | 1554.13nm | Max Cable Distance | 40km |
| Connector | Duplex LC | Media | SMF |
| Transmitter Type | EML | Receiver Type | PIN |
| TX Power | -1 to +2dBm | RX Power | -16 to -1dBm |
| Receiver Sensitivity | -15.5dBm | DDM/DOM | Supported |
| Operating Temperature Range | 0 to 70°C | Protocols | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 |
LINK-PP LS-DW2910-40C integrates 10G SFP+ DWDM technology to deliver reliable 1554.13nm transmission up to 40km over single-mode fiber. Featuring a duplex LC interface and real-time DOM monitoring, it combines standard SFP+ compliance with exceptional fiber efficiency for modern optical networks.
The transceiver features a hot-pluggable SFP+ footprint that allows easy installation without powering down host systems. It fully complies with the SFP+ MSA standard to ensure smooth integration across standard optical networking hardware.
Operating at a stable 10Gbps data rate, this module provides the steady bandwidth required for metro data center interconnects. This reliable transmission speed helps enterprise sites and regional hubs exchange large volumes of traffic without bottlenecks.
Dense Wavelength Division Multiplexing enables multiple optical channels to run concurrently across an existing single fiber pair. This channel-combining capability expands total network capacity without the heavy expense of laying new optical cabling.
Channel 29 is centered precisely at the 1554.13nm wavelength on the standard 100GHz ITU grid. This precise spectral alignment ensures clean channel separation and minimizes crosstalk when multiplexed with adjacent C-band signals.
A cooled EML transmitter paired with a sensitive PIN photodiode enables long-reach links up to 40km over standard single-mode fiber. This substantial optical reach bridges remote campus facilities and metro sites without requiring intermediate signal repeaters.
The duplex LC optical connector provides a secure, compact physical latching interface. This familiar design ensures seamless pairing with existing single-mode patch cords and optical distribution panels.
Built-in Digital Optical Monitoring is compatible with SFF-8472 digital diagnostics functions to track parameters like temperature, optical power, and bias current. Network administrators can access these real-time metrics through the host system to quickly identify potential link faults.
LINK-PP LS-DW2910-40C 10G DWDM module complies with strict international standards, holding certifications including ISO 9001, CE, RoHS, and FCC; this comprehensive certification set confirms reliable environmental safety, product quality, and electromagnetic compliance.
Every DWDM SFP+ transceiver undergoes rigorous bit error rate and optical eye pattern testing before shipping, which ensures flawless signal performance across demanding data links.
The module adheres to internationally recognized regulatory frameworks and environmental safety standards, ensuring consistent production reliability for commercial enterprise deployments.
Standardized EEPROM programming and protocol testing enable seamless recognition across various OEM switches, which prevents port errors and simplifies hardware installation.
LINK-PP validates every 10G DWDM SFP+ transceiver through multi-stage physical layer verification to guarantee zero packet loss across standard operating environments; discover full testing procedures at the LINK-PP Test Support Center.
Verify wavelength precision to prevent adjacent channel optical interference.
Measure transmitter signal quality to ensure clean optical pulse shapes.
Check data transmission integrity to eliminate packet drop across links.
Assess thermal stability across full operating ranges for long-term reliability.
LINK-PP uses standardized protective packaging and trusted courier networks to safeguard every DWDM SFP+ optical module during transit. This streamlined shipping process ensures rapid, damage-free order fulfillment worldwide.
Shield delicate electronic components against electrostatic discharge damage during handling.
Safeguard optical transceivers against accidental impacts throughout continuous physical transit.
Prepare and release customer shipments quickly to minimize project downtime.
Partner with reputable freight carriers to provide dependable worldwide shipments.
To deploy the LS-DW2910-40C 10G DWDM transceiver, insert this hot-pluggable module into an SFP+ switch slot, remove dust caps, and mate standard duplex LC patch cables to a 100GHz DWDM multiplexer. This straightforward setup delivers dependable 10G connectivity across regional metro DCI networks up to 40km.
LINK-PP offers end-to-end technical support, from pre-sales consultation to post-deployment assistance, ensuring smooth integration and reliable network performance.
Professional guidance to help you select the optimal LS-DW2910-40C module for your network design and application needs.
Validated compatibility with LINK-PP switches and other mainstream networking platforms for seamless deployment.
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
LINK-PP provides after-sales support for the smooth deployment and reliable operation of the optical modules.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
![]() LS-DW1710-A0C
| ![]() LS-CW5510-10I
| ![]() LS-DW6110-80I
| ![]() LS-DW4610-40I
| ![]() LS-DW4510-40I
|
|---|
Compatible | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP |
Data Rate (Max) | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps |
Wavelength | 1554.13nm | 1563.86nm | 1550nm | 1528.77nm | 1540.55nm | 1541.34nm |
Connector | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC |
Cable Distance (Max) | 40km | 100km | 10km | 80km | 40km | 40km |
Cable Type | SMF | SMF | SMF | SMF | SMF | SMF |
TX Power | -1 to +2dBm | -1 to +5dBm | -5 to +1dBm | -1 to +5dBm | -1 to +2dBm | -1 to +2dBm |
Receiver Sensitivity | -15.5dBm | -23dBm | -16 to -1dBm | -23dBm | -16 to -1dBm | -16 to -1dBm |
Operating Temperature | 0 to 70°C | 0 to 70°C | -40 to 85°C | -40 to 85°C | -40 to 85°C | -40 to 85°C |
Temperature | Commercial | Commercial | Industrial | Industrial | Industrial | Industrial |
Form Factor | SFP+ | SFP+ | SFP+ | SFP+ | SFP+ | SFP+ |
Transmitter Type | EML | EML | DFB | EML | EML | EML |
Receiver Type | PIN | APD | PIN | APD | PIN | PIN |
DDM/DOM | Supported | Supported | Supported | Supported | Supported | Supported |
Protocols | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA Compliant | SFP+ MSA, SFF-8472, ITU-T G.652 | 10GBASE-ZR/ZW, SDH STM64, SFF-8431, SFF-8472 | SFP+ MSA, SFF-8431, SFF 8472, 10GBASE-ER/EW, SDH STM64 | SFP+ MSA, SFF-8431, SFF 8472, 10GBASE-ER/EW, SDH STM64 |
| Pictures | ID# | Description | Price | Stock | Add to Cart |
Q: Our fiber route has several LC patch points. Is that a concern for this DWDM module? By P***y
A: Multiple patch points add insertion loss, so the full path should be included in the optical-budget check. DOM receive-power readings can help verify the installed margin after the link is turned up. By admin
A: The module is rated for commercial operating temperatures between 0 and 70°C, and its internal EML laser utilizes thermoelectric temperature control to keep the 1554.13nm wavelength stable. As long as closet ambient conditions allow switch fans to keep internal module temps below 70°C, link performance remains reliable. By admin
Q: How does fiber bending affect the transmission quality of this 1554.13nm optical signal? By J***r
A: The 1550nm wavelength region is slightly more sensitive to macro-bending losses than shorter wavelengths like 1310nm. Maintaining proper bend radiuses along fiber trays prevents localized attenuation from degrading your received signal margin. By admin
Q: The receive reading dropped after a patch cord change. Does that point to the module? By R***s
A: A lower RX value may come from the new patch cord, connector cleanliness, or a changed fiber path rather than the module itself. Rechecking the connectors and comparing with the pre-change baseline can help isolate the cause. By admin
Q: Can I connect this C29 transceiver to a patch panel terminated with standard OS2 single-mode fiber? By K***s
A: Yes, OS2 single-mode fiber is generally suitable for this 1554.13nm DWDM module when the patch panel and fiber path use compatible LC single-mode connections. Check the complete link budget, including fiber, patch-panel, connector, splice, and DWDM mux losses, before deployment. By admin
United States
Carrier
CostDelivery TimeTracking
Company
CostTime
To Be Negotiated Available