All Products
Compatible Optics
Services
Support
About Us
Resources
OEM-coded optical modules for major platforms
Curated album pages for cages and copper optics
Mind your business with a variety of trusted payment options.
Use order number or tracking number to check shipping status.
Get your quote fast and offer you more professional service.
Help manage your budget & expenditure better.
Free samples support, achieve your test results efficiently.
Professional team support and service, to solve your problems in time.
Ask us whatever you care, we will help you 24/7.
Get your quote fast and offer you more professional service.
Meet us and know our mission, belief, service and more.
Find our locations and get connected with us closely.
Quality management, testing, compatibility and global compliance.
Find out the latest news and events around l-p.com
Deep dive into technical guides, industry standards, and SFP compatibility insights.
Detailed product benchmarks and side-by-side comparisons to help you choose the right module.
Explore real-world connectivity solutions for data centers, enterprises, and telecom networks.
Essential tips on choosing data rates, transmission distances, and connector types.
New Customer? Create an account
DWDM-SFP10G-36.61-80 SFP+ module provides fixed 10G DWDM connectivity tuned to the 1536.61nm (Channel 51, 100GHz grid) optical channel within the C-band. Designed for point-to-point links reaching up to 80km over SMF, it combines a cooled EML laser, an APD receiver, and built-in real-time digital diagnostic monitoring for comprehensive link-state visibility.
| HPE Part Number | DWDM-SFP10G-36.61-80 | Vendor Name | LINK-PP |
| Form Factor | SFP+ | Max Data Rate | 10.7Gbps |
| Wavelength | 1536.61nm | Max Cable Distance | 80km |
| Connector | Duplex LC | Media | SMF |
| Transmitter Type | EML | Receiver Type | APD |
| TX Power | -1 to +5dBm | RX Power | -23 to -6dBm |
| Receiver Sensitivity | -23dBm | DDM/DOM | Supported |
| Operating Temperature Range | 0 to 70°C | Protocols | 10GBASE-ZR/ZW, SDH STM64, SFF-8431, SFF-8472 |
HPE DWDM-SFP10G-36.61-80 Compatible LINK-PP serves as a dedicated 10G SFP+ optical module built for high-density DWDM fiber links. It integrates a stable 1536.61nm wavelength, long-haul 80km optical reach, dual LC fiber connectors, and continuous real-time diagnostic telemetry.
This transceiver features a hot-pluggable SFP+ footprint for fast installation without powering down host systems. It fully complies with the SFP+ MSA standard to ensure seamless physical compatibility across commercial networking hardware.
Continuous 10Gbps data throughput delivers stable bandwidth across dedicated campus point-to-point connections. Network administrators can easily interconnect distant aggregation switches and core routing nodes at line-rate speeds.
Dense Wavelength Division Multiplexing technology allows multiple channels to transmit simultaneously over a single optical path. This multiplexing capability maximizes existing fiber utilization without requiring additional cable installations.
Channel 51 (C51) operation is fixed at a 1536.61nm optical wavelength on the 100GHz ITU grid. The laser transmitter maintains tight spectral stability across the DWDM C-band to prevent adjacent-channel interference.
Long-haul transmission capabilities enable single-mode fiber spans of up to 80km between network endpoints. An integrated cooled EML laser paired with an APD receiver maintains optical link budgets over extended distances.
The duplex LC optical connector provides a secure physical interface for single-mode patch cables. The compact latching mechanism ensures consistent optical alignment and simplified fiber patching in dense patch panels.
Built-in digital diagnostic monitoring complies with SFF-8472 specifications to provide live visibility into critical parameters. Operating temperature, laser bias current, supply voltage, and optical power levels can be tracked in real time to simplify preventive maintenance.
The HPE DWDM-SFP10G-36.61-80 Compatible LINK-PP 10G SFP+ module meets strict global quality and safety standards for commercial network equipment. It proudly holds major industry certifications, including ISO 9001, CE, RoHS, and FCC, to ensure safe and reliable operation.
Every 10G DWDM optical transceiver goes through a rigorous quality testing process before leaving the factory. This comprehensive program includes strict optical parameter checks and temperature testing to guarantee stable data transmission over long distances.
This optical module strictly complies with essential international environmental and electromagnetic safety guidelines. These official endorsements prove that the hardware is securely built for long-term deployment in commercial enterprise networks.
Our engineers thoroughly test each module on popular brand-name switches and routers to ensure seamless network integration. This verified plug-and-play compatibility allows network administrators to upgrade their equipment with complete confidence.
Strict testing evaluations guarantee seamless optical performance and long-term transmission reliability under demanding network conditions. Discover our complete testing procedures by visiting the LINK-PP Test Support Center.
Analyze laser wavelength precision to prevent adjacent DWDM channel interference.
Assess optical transmitter waveform clarity to minimize high-speed signal distortion.
Confirm flawless packet delivery across maximum single-mode optical fiber distances.
Validate component thermal endurance under extreme commercial operating conditions.
We use secure packaging and reliable courier networks to deliver your optical modules safely worldwide. Every order is handled carefully to ensure your transceivers arrive on schedule and ready for installation.
Protect sensitive optical components against unexpected electrostatic discharge during storage.
Shield delicate transceiver hardware against accidental vibrations during long-distance transit.
Prepare and release confirmed customer orders quickly from our warehouse.
Deliver transceiver modules efficiently across major international cargo corridors.
To deploy the DWDM-SFP10G-36.61-80 module, insert it into a compatible SFP+ switch slot and connect duplex LC single-mode patch cords linked to a DWDM MUX/DEMUX. This hot-pluggable setup establishes high-capacity 10Gbps campus point-to-point links, seamlessly bridging core network switches between distant campus buildings.
LINK-PP offers end-to-end technical support, from pre-sales consultation to post-deployment assistance, ensuring smooth integration and reliable network performance.
Professional guidance to help you select the optimal DWDM-SFP10G-36.61-80 module for your network design and application needs.
Validated compatibility with LINK-PP switches and other mainstream networking platforms for seamless deployment.
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
LINK-PP provides after-sales support for the smooth deployment and reliable operation of the optical modules.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
| Pictures | ID# | Description | Price | Stock | Add to Cart |
A: This DWDM module is tuned to standard ITU Channel 51 at 1536.61nm with 100GHz grid spacing. It is intended to align directly with the corresponding C51 port on standard 100GHz C-band Mux/Demux units, which helps avoid adjacent channel cross-talk. By admin
A: The duplex LC receptacle matches standard single-mode fiber (SMF) connectors commonly found in data center patching. Simply ensure the connector end-faces are clean to minimize insertion loss across long fiber runs. By admin
A: With an operating case rating up to 70°C, the cooled EML laser is designed to hold wavelength stability across elevated temperatures. Keeping standard cabinet ventilation running usually provides ample cooling headroom. By admin
A: Yes, the hot-pluggable SFP+ footprint allows safe insertion and removal while the router chassis is powered on. This ensures maintenance can be completed quickly without disturbing adjacent live service ports. By admin
United States
Carrier
CostDelivery TimeTracking
Company
CostTime
To Be Negotiated Available