All Products
Services
Support
About Us
Resources
Mind your business with a variety of trusted payment options.
Use order number or tracking number to check shipping status.
Get your quote fast and offer you more professional service.
Help manage your budget & expenditure better.
Free samples support, achieve your test results efficiently.
Professional team support and service, to solve your problems in time.
Ask us whatever you care, we will help you 24/7.
Get your quote fast and offer you more professional service.
Meet us and know our mission, belief, service and more.
Find our locations and get connected with us closely.
Quality management, testing, compatibility and global compliance.
Download ISO, CE, FCC, UL, RoHS and REACH certificates by product line.
Lab tour, optical test bed, compatibility tool and test requests.
Find out the latest news and events around l-p.com
Deep dive into technical guides, industry standards, and SFP compatibility insights.
Detailed product benchmarks and side-by-side comparisons to help you choose the right module.
Explore real-world connectivity solutions for data centers, enterprises, and telecom networks.
Essential tips on choosing data rates, transmission distances, and connector types.
New Customer? Create an account
LS-SM3125-02C defines a 25G SFP28 optical transceiver that operates at 1310nm over duplex LC/UPC-terminated single-mode fiber, delivering error-free transmission up to 2km while incorporating real-time DOM diagnostics for precise link monitoring.
| LINK-PP Part Number | LS-SM3125-02C | Vendor Name | LINK-PP |
| Form Factor | SFP28 | Max Data Rate | 25.78Gbps |
| Wavelength | 1310nm | Max Cable Distance | 2km |
| Connector | Duplex LC | Media | SMF |
| Transmitter Type | DFB | Receiver Type |
PIN |
| Tx Power | 8 to +3dBm | Rx Power |
-14 to +3dBm |
| Receiver Sensitivity | -13.3dBm | Operating Temperature range | 0°C to +70°C |
| Protocols | MSA Compliant, CPRI, eCPRI | Warranty | 5 Years |
LINK-PP LS-SM3125-02C is a 25G SFP28 transceiver that combines a 1310nm DFB laser, a PIN photodiode, and a duplex LC/UPC interface for 2km single‑mode fiber links. It includes digital DOM for real‑time signal monitoring and supports stable operation across a wide temperature range. Together, these features make the module a reliable choice for short‑reach metro and access connections.
This module is built around a 1310nm DFB transmitter and a PIN receiver. The DFB delivers low chromatic dispersion, while the PIN ensures sufficient sensitivity for the 2km reach. Both components are integrated in a standard SFP28 form factor.
Designed for metro access networks, this module provides 25Gbps data rate over existing single‑mode fiber infrastructure. Its 2km range covers typical aggregation and edge connections, reducing the need for additional signal regeneration.
The 1310nm wavelength offers a well‑balanced operating window with low attenuation in standard single‑mode fiber. It also avoids the cost and complexity of longer‑reach 1550nm optics while maintaining good performance for short‑distance links.
With a transmission distance of up to 2km, this module is ideal for intra‑building, campus, or metro edge deployments. It easily covers the reach required for most rack‑to‑rack and floor‑to‑floor connections without using external amplifiers.
The duplex LC/UPC connector ensures quick and secure mating with standard fiber patch cords. Its UPC polish minimizes back reflection, which helps maintain signal integrity in bidirectional data links.
Digital Optical Monitoring (DOM) provides real‑time access to parameters such as transmitter power, receiver power, temperature, and supply voltage. This feature enables proactive link health checks and simplifies troubleshooting during network operation.
LINK-PP LS-SM3125-02C meets international standards such as ISO 9001, CE, RoHS, and FCC to ensure product quality and compliance.
Each module undergoes strict testing procedures to verify stable optical and electrical performance.
The module follows recognized industry standards to ensure consistent manufacturing and product reliability.
It is tested for compatibility with various networking devices to ensure stable and seamless operation.
LINK-PP LS-SM3125-02C passes multiple tests to ensure stable 25G transmission and consistent quality. For further details, refer to the LINK-PP Test Support Center.
Verify wavelength accuracy and output power levels.
Check signal quality via open eye diagrams.
Measure error counts under various data patterns.
Test performance from cold start to hot operation.
LINK-PP LS-SM3125-02C is carefully prepared to ensure safe delivery and product integrity. Orders are handled quickly with reliable global shipping services.
Protect modules from static damage during handling and shipping.
Reduce impact risks during transportation and handling.
Ensure quick processing and timely shipment of orders.
Support worldwide shipping with reliable delivery services.
To operate, simply insert the LS-SM3125-02C SFP28 transceiver into a compatible host, attach the single-mode fiber with duplex LC connectors, and verify link status via DOM. This module supports 25G Ethernet for data center top-of-rack, inter-rack, and edge aggregation, making it a straightforward solution for dense network environments.
LINK-PP offers end-to-end technical support, from pre-sales consultation to post-deployment assistance, ensuring smooth integration and reliable network performance.
Professional guidance to help you select the optimal LS-SM3125-02C module for your network design and application needs.
Validated compatibility with LINK-PP switches and other mainstream networking platforms for seamless deployment.
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
LINK-PP provides after-sales support for the smooth deployment and reliable operation of the optical modules.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
Compatible | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP |
Data Rate (Max) | 25.78Gbps | 25.78Gbps | 25.78Gbps | 25.78Gbps | 25.78Gbps | 10/25.78Gbps |
Wavelength | 1310nm | 1310nm | 1310nm | 1310nm | 1310nm | 850nm |
Connector | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC |
Cable Distance (Max) | 2km | 30km | 40km | 10km | 20km | 100m |
Cable Type | SMF | SMF | SMF | SMF | SMF | MMF |
TX Power | 8 to +3dBm | -8 to +3dBm | -1 to +7dBm | -8.4~2.4dBm | ||
Receiver Sensitivity | -13.3dBm | -19dBm | -19dBm | -14 to +3dBm | -15 to +3dBm | <-10.3dBm |
Operating Temperature | 0°C to +70°C | 0°C to +70°C | 0°C to +70°C | -40 to 85°C | -40°C to +85°C | 0°C to +70°C |
Form Factor | SFP28 | SFP28 | SFP28 | SFP28 | SFP28 | SFP28 |
Transmitter Type | DFB | EML | EML | DFB | DFB | VCSEL |
Receiver Type | PIN | APD | APD/TIA | PIN | PIN | PIN |
Protocols | MSA Compliant, CPRI, eCPRI | MSA Compliant, CPRI, eCPRI | MSA Compliant, CPRI, eCPRI | SFF-8472, SFF-8402, SFF-8432, SFF-8431, CEI-28G-VSR | MSA Compliant, CPRI, eCPRI | SFF-8472, SFF-8024, SFF-8431, SFF-8432 |
Warranty | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years |
| Pictures | ID# | Description | Price | Stock | Add to Cart |
Q: Is the pull-tab robust enough to handle frequent hot-swapping during active datacenter maintenance cycles? By B***y on 2026-04-21
A: Yes, the high-strength structural pull-tab is specifically engineered to endure repeated extraction cycles in high-density rack configurations. By admin on 2026-04-22
Q: Can I patch this 25G optical transceiver directly into an existing multi-mode OM3/OM4 fiber infrastructure? By D***e on 2026-01-29
A: No, this module requires single-mode fiber to operate correctly; attempting to use multi-mode fiber will result in severe signal loss. By admin on 2026-01-30
Q: Does this 25G SFP28 optical module support real-time digital diagnostic monitoring via standard SNMP? By C***d on 2025-11-04
A: Yes, it features full DDM/DOM compliance per SFF-8472, allowing you to monitor real-time temperature, supply voltage, laser bias current, and optical power via your network management software. By admin on 2025-11-05
Q: Will a complete fiber polarity error (reversed Tx/Rx strands) show up in our software as an uneven optical power alert? By E***n on 2025-08-11
A: No, a full polarity crossover results in a complete Loss of Signal (LOS) across all channels, shifting the interface status directly to link-down. By admin on 2025-08-12
Q: We need to purchase 500 pieces of these 2km 25G QSFP28 optical transceivers for a data center overhaul. Do you offer bulk order discounts? By A***y on 2025-03-13
A: Yes, we offer tiered wholesale pricing and customized quotes for volume corporate orders; please contact our sales support team directly. By admin on 2025-03-14
{{reply_items.topic || reply_items.text}}By {{reply_items.author}}
{{ lpMoneyText(detail_data.displayed_price.unit_prefix, item.displayed_price.value || item.displayed_price.min, detail_data.displayed_price.unit_suffix) }}
Singapore
Carrier
CostDelivery TimeTracking
Company
CostTime
{{ shipitem.name }}
{{ isFreeShipping(shipitem)? 'Free Shipping' : lpMoneyText(detail_data.displayed_price.unit_prefix, shipitem.price, detail_data.displayed_price.unit_suffix) }} To Be Negotiated {{shipitem.datemin}}-{{shipitem.datemax}} days Available
{{parseInt(detail_data.left_num) ? detail_data.left_num +' in Stock' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}}