All Products
Services
Support
About Us
Resources
Mind your business with a variety of trusted payment options.
Use order number or tracking number to check shipping status.
Get your quote fast and offer you more professional service.
Help manage your budget & expenditure better.
Free samples support, achieve your test results efficiently.
Professional team support and service, to solve your problems in time.
Ask us whatever you care, we will help you 24/7.
Get your quote fast and offer you more professional service.
Meet us and know our mission, belief, service and more.
Find our locations and get connected with us closely.
Quality management, testing, compatibility and global compliance.
Download ISO, CE, FCC, UL, RoHS and REACH certificates by product line.
Lab tour, optical test bed, compatibility tool and test requests.
Find out the latest news and events around l-p.com
Deep dive into technical guides, industry standards, and SFP compatibility insights.
Detailed product benchmarks and side-by-side comparisons to help you choose the right module.
Explore real-world connectivity solutions for data centers, enterprises, and telecom networks.
Essential tips on choosing data rates, transmission distances, and connector types.
New Customer? Create an account
XBR-SFP10G1570-10 optical module delivers 10G SFP+ connectivity at the 1570nm CWDM wavelength, integrating a DFB laser transmitter and PIN photodiode receiver to support duplex LC transmissions up to 10km over single-mode fiber while providing real-time digital optical monitoring for granular insight into operational metrics.
| Brocade Part Number | XBR-SFP10G1570-10 | Vendor Name | LINK-PP |
| Form Factor | SFP+ | Max Data Rate | 10.7 Gbps |
| Wavelength | 1570nm | Max Cable Distance | 10km |
| Connector | Duplex LC | Media | SMF |
| Receiver Type | DFB | Transmitter Type | PIN |
| TX Power | -5 to +1dBm | RX Power | -16 to -1dBm |
| Receiver Sensitivity | <-14.5dBm | Receiver Overload | 0.5dBm |
| Operating Temperature Range | 0 to 70°C | Protocols | SFP+ MSA Compliant, SFF 8472,SFF 8431,802.3ae, ITU-T G.652 |
Brocade XBR-SFP10G1570-10 Compatible LINK-PP module is a commercial-grade 10G SFP+ CWDM transceiver designed for reliable, multi-channel metro and data center links over single-mode fiber. It combines a hot-pluggable SFP+ form factor, CWDM wavelength efficiency at 1570nm, 10km reach, duplex LC connectivity, and real-time DOM monitoring in a compact, standards-compliant module.
The XBR-SFP10G1570-10 uses a hot-pluggable SFP+ footprint for easy installation and replacement without powering down the system. It is compliant with the SFP+ MSA and SFF-8472 specifications, ensuring broad switch and router compatibility as well as standardized mechanical and electrical interfaces.
Designed for next-generation network infrastructure, the XBR-SFP10G1570-10 provides robust 10Gbps data transmission for enterprise, storage, and metro links. It enables efficient network expansion and high-speed data flow while maximizing existing fiber investments.
CWDM technology enables multiple wavelengths to coexist on the same fiber, reducing the number of fibers required for multi-service deployment. This approach simplifies network planning and lowers cost per bit in point-to-point and ring topologies that use 10G links.
Operating at a 1570nm CWDM wavelength, this transceiver fits into the standard 18-channel CWDM grid used in many metro and access networks. The 1570nm channel is well-suited for long-reach single-mode links where low attenuation and compatibility with existing CWDM infrastructure are important.
The optical budget and component design support transmission distances up to 10km over standard single-mode fiber (SMF). This reach covers most intra-city, campus, and data center interconnect scenarios that require reliable 10G connectivity without amplification.
A duplex LC connector provides a compact, industry-standard interface for transmit and receive fibers in a single module. This design simplifies patching, improves port density on switches, and matches the cabling used in most 10G SFP+ deployments.
Built-in DOM (Digital Optical Monitoring) allows real-time tracking of key parameters such as temperature, supply voltage, TX/RX power, and bias current. These diagnostics help with proactive maintenance, link troubleshooting, and performance verification in production networks.
Brocade XBR-SFP10G1570-10 Compatible LINK-PP module is built under ISO 9001 quality management and carries CE, RoHS, and FCC approvals for global market access.
Each transceiver is screened through electrical, optical, and environmental checks to confirm stable operation before it leaves the factory.
The module holds key industry certifications that validate its compliance with international electromagnetic, safety, and hazardous substance regulations.
Extensive host testing and multi-vendor compatibility checks guarantee smooth system integration, effortless deployment, and consistent connection stability across network devices.
Brocade XBR-SFP10G1570-10 Compatible LINK-PP SFP+ module undergoes strict optical, electrical, and environmental checks to deliver stable 10G links in real networks. Visit the LINK-PP Test Support Center for deeper insights into our test procedures and criteria.
Confirm CWDM wavelength placement and spectral purity for clean channel spacing.
Validate signal quality and timing margins against 10G Ethernet eye-diagram requirements.
Stress the link to verify ultra-low BER and consistent 10Gbps throughput.
Run thermal cycling to prove stable operation across the full commercial temperature range.
Brocade XBR-SFP10G1570-10 Compatible LINK-PP module ships in ESD-safe packs to protect sensitive optics. Orders are processed fast and dispatched to global destinations reliably.
Use anti-static bags to block static during storage and transit.
Durable cartons minimizes damage from shocks and impacts.
Process orders swiftly and hand them over to carriers for prompt dispatch.
Ship worldwide via trusted couriers to ensure smooth, hassle-free cross-border delivery.
Install Brocade XBR-SFP10G1570-10 Compatible LINK-PP CWDM 10G SFP+ module by hot-plugging into the switch, connecting duplex LC cables, and enabling the 10G interface for CWDM transport. It fits metro edge, campus backbone, and multi-service ring designs that rely on 1570nm channels and 10km single-mode reach.
LINK-PP offers end-to-end technical support, from pre-sales consultation to post-deployment assistance, ensuring smooth integration and reliable network performance.
Professional guidance to help you select the optimal XBR-SFP10G1570-10 module for your network design and application needs.
Validated compatibility with LINK-PP switches and other mainstream networking platforms for seamless deployment.
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
LINK-PP provides after-sales support for the smooth deployment and reliable operation of the optical modules.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
![]() LS‑DW4010‑40C
| ![]() LS-DW3910-40C
| ![]() LS-DW3810-40C
| ![]() LS-DW3710-40C
| ![]() LS-DW3610-40C
|
|---|
Compatible | Brocade | Brocade | Brocade | Brocade | Brocade | Brocade |
Data Rate (Max) | 10.7 Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps |
Wavelength | 1570nm | 1545.32nm | 1546.12nm | 1546.92nm | 1547.71nm | 1548.51nm |
Connector | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC |
Cable Distance (Max) | 10km | 40km | 40km | 40km | 40km | 40km |
Cable Type | SMF | SMF | SMF | SMF | SMF | SMF |
TX Power | -5 to +1dBm | -1 to +2dBm | -1 to +2dBm | -1 to +2dBm | -1 to +2dBm | -1 to +2dBm |
Receiver Sensitivity | -16 to -1dBm | -15.5dBm | -15.5dBm | -15.5dBm | -15.5dBm | -15.5dBm |
Operating Temperature | 0 to 70°C | 0 to 70°C | 0 to 70°C | 0 to 70°C | 0 to 70°C | 0 to 70°C |
Vendor Name | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP |
Brocade Part Number | XBR-SFP10G1570-10 | 10G-SFPP-ZRD-1545.32 | 10G-SFPP-ZRD-1546.12 | 10G-SFPP-ZRD-1546.92 | 10G-SFPP-ZRD-1547.72 | 10G-SFPP-ZRD-1548.51 |
Temperature | Commercial | Commercial | Commercial | Commercial | Commercial | Commercial |
Form Factor | SFP+ | SFP+ | SFP+ | SFP+ | SFP+ | SFP+ |
Receiver Type | DFB | PIN | PIN | PIN | PIN | PIN |
Transmitter Type | PIN | EML | EML | EML | EML | EML |
Receiver Overload | 0.5dBm | |||||
Protocols | SFP+ MSA Compliant, SFF 8472,SFF 8431,802.3ae, ITU-T G.652 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 |
| Pictures | ID# | Description | Price | Stock | Add to Cart |
Q: Can we mix this 1570nm channel with 1490nm and 1530nm on the same 8-channel CWDM mux without crosstalk issues? By T***n on 2026-03-25
A: Yes, 1570nm is part of the standard ITU-T G.694.2 CWDM grid and coexists cleanly with 1490/1530nm on typical 8-channel mux/demux systems. By admin on 2026-03-26
Q: Do I need to reboot our top-of-rack switch when inserting this module into an active port? By V***m on 2025-08-24
A: No reboot is needed. The module features a hot-pluggable SFP+ footprint for live installation. By admin on 2025-08-25
Q: Can we plug our existing multi-mode LC patch cables into this 1570nm CWDM transceiver for short links? By S***t on 2025-04-04
A: No, this CWDM 10km SFP transceiver requires single-mode fiber with duplex LC connectors for correct optical transmission. By admin on 2025-04-05
{{reply_items.topic || reply_items.text}}By {{reply_items.author}}
{{ lpMoneyText(detail_data.displayed_price.unit_prefix, item.displayed_price.value || item.displayed_price.min, detail_data.displayed_price.unit_suffix) }}
United Kingdom
Carrier
CostDelivery TimeTracking
Company
CostTime
{{ shipitem.name }}
{{ isFreeShipping(shipitem)? 'Free Shipping' : lpMoneyText(detail_data.displayed_price.unit_prefix, shipitem.price, detail_data.displayed_price.unit_suffix) }} To Be Negotiated {{shipitem.datemin}}-{{shipitem.datemax}} days Available
{{parseInt(detail_data.left_num) ? detail_data.left_num +' in Stock' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}}