All Products
Services
Support
About Us
Resources
Mind your business with a variety of trusted payment options.
Use order number or tracking number to check shipping status.
Get your quote fast and offer you more professional service.
Help manage your budget & expenditure better.
Free samples support, achieve your test results efficiently.
Professional team support and service, to solve your problems in time.
Ask us whatever you care, we will help you 24/7.
Get your quote fast and offer you more professional service.
Meet us and know our mission, belief, service and more.
Find our locations and get connected with us closely.
Quality management, testing, compatibility and global compliance.
Download ISO, CE, FCC, UL, RoHS and REACH certificates by product line.
Lab tour, optical test bed, compatibility tool and test requests.
Find out the latest news and events around l-p.com
Deep dive into technical guides, industry standards, and SFP compatibility insights.
Detailed product benchmarks and side-by-side comparisons to help you choose the right module.
Explore real-world connectivity solutions for data centers, enterprises, and telecom networks.
Essential tips on choosing data rates, transmission distances, and connector types.
New Customer? Create an account
The LINK-PP LQ-BLB100-ZR4C 100G QSFP28 BiDi optical transceiver supports an aggregate data rate of 103.125 Gbps over single-mode fiber (SMF) using LAN-WDM technology. It transmits on four wavelengths of 1295.56 nm, 1300.05 nm, 1304.58 nm, and 1309.14 nm, and receives on 1273.55 nm, 1277.89 nm, 1282.26 nm, and 1286.66 nm. Designed for 80 km simplex LC links, it delivers reliable 100G optical connectivity and is fully verified for seamless interoperability within LINK-PP networking platforms.
| LINK-PP Part Number | LQ-BLB100-ZR4C | Vendor Name | LINK-PP |
| Form Factor | QSFP28 | Max Data Rate | 103.125Gbps |
| Wavelength |
TX:1295.56, 1300.05, 1304.58, 1309.14 RX: 1273.55, 1277.89, 1282.26, 1286.66 |
Max Cable Distance | 80km |
| Connector | Simplex LC | Media | SMF |
| Transmitter Type | EML | Receiver Type |
PIN |
| Modulation (Electrical) | 4x 25G NRZ | Modulation (Optical) | 4x 25G NRZ |
| Power Consumption | ≤3.3W | Protocols | QSFP28 MSA, SFF-8636, IEEE 802.3ba 100Gbase-ER4 |
| DDM/DOM | Supported | Operating Temperature Range | 0°C to +70°C |
The LINK-PP LQ-BLB100-ZR4C is a high-performance 100G QSFP28 BiDi optical transceiver designed for long-reach metro and regional links. Delivering a native data rate of 103.125 Gbps over SMF, this compact, hot-pluggable QSFP28 supports link lengths up to 80 km while providing full Digital Optical Monitoring for real-time diagnostics.
Built with LAN WDM EML lasers and PIN receivers featuring SOA, this BiDi QSFP28 module combines ultra-high-speed electrical I/O with carrier-grade optical reliability.
With a maximum data rate of 103.125 Gbps, the LINK-PP LQ-BLB100-ZR4C 100G QSFP28 BiDi is designed to support high-bandwidth network environments that demand fast, stable, and scalable data transmission.
The LQ-BLB100-ZR4C module employs LAN-WDM technology with four transmit wavelengths of 1295.56 nm, 1300.05 nm, 1304.58 nm, and 1309.14 nm, and four receive wavelengths of 1273.55 nm, 1277.89 nm, 1282.26 nm, and 1286.66 nm. This BiDi LAN-WDM architecture enables 100G transmission over a single LC fiber, improves fiber utilization, simplifies cabling, and delivers stable, long-distance optical connectivity for high-capacity network deployments.
Engineered for long-range connectivity, this 100G BiDi module supports transmission distances up to 80 km over single-mode fiber. This capability makes it ideal for metro network expansion, inter-building connectivity, regional backbone networks, and long-distance enterprise infrastructure.
The simplex LC/UPC optical interface enables both transmit and receive signals to operate through a single fiber connector. This results in simpler cabling, faster installation, and reduced infrastructure costs, particularly in high-density data centers and carrier environments.
This LINK-PP LQ-BLB100-ZR4C 100G QSFP28 module supports Digital Optical Monitoring (DOM) via the I2C interface, enabling you to monitor critical operating parameters in real time.
The LINK-PP LQ-BLB100-ZR4C optical transceiver is manufactured in accordance with ISO 9001 quality management standards and is certified to the CE, RoHS, and FCC standards.
From optical performance and signal integrity testing to environmental reliability verification, every LQ-BLB100-ZR4C module is thoroughly tested to ensure stable and dependable 100G network performance.
Extensive manufacturing and validation procedures confirm consistent module performance, ensuring long operational lifecycles and dependable reliability in demanding networking environments.
LINK-PP host platforms are tested with compatible optical modules to verify system-level interoperability.
Every module is carefully validated for signal integrity and operational stability to minimize failures and maximize network availability. To learn more, visit the LINK-PP Test Support Center.
Verifies wavelength accuracy to guarantee channel performance that meets established standards.
Checks for clear eye patterns to ensure consistent and reliable high-speed data transfer.
Confirms low error rates to maintain dependable link quality.
Assesses reliable functioning under a wide range of environmental temperatures.
Your modules arrive ready to deploy. LINK-PP protects every unit with anti-static and shock-resistant packaging, backed by fast processing and reliable worldwide shipping.
Superior anti-static bags prevent ESD exposure in storage and transport.
Reinforced packing cushions against shocks.
Optimized workflows accelerate order processing.
International carriers maintain consistent delivery performance.
The QSFP28 optical module employs BiDi (Bidirectional) optical technology, allowing both transmit and receive signals to travel over a single strand of fiber using two different wavelengths. It is ideally suited for data center interconnect (DCI), metro optical networks, carrier backbone infrastructure, enterprise long-distance networking, and high-capacity cloud connectivity.
LINK-PP provides professional technical support, including pre-sales consultation, compatibility verification, and post-deployment troubleshooting to ensure smooth network operation.
Professional technical guidance to help customers select the most suitable LQ-BLB100-ZR4C modules based on network architecture and application requirements.
Compatibility checks and validation to ensure seamless operation with Cisco switches and other supported networking platforms.
Step-by-step support for installation, configuration, and initial deployment to ensure stable and correct operation.
Ongoing technical support throughout the product lifecycle to ensure reliable performance in enterprise and carrier-grade networks.
LINK-PP provides after-sales support for the smooth deployment and reliable operation of the optical modules.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
![]() Current Model LQ-BLB100-ZR4C |
|---|
Compatible | LINK-PP | LINK-PP |
Data Rate (Max) | 103.125Gbps | 103.125Gbps |
Wavelength | TX:1295.56, 1300.05, 1304.58, 1309.14 RX: 1273.55, 1277.89, 1282.26, 1286.66 | TX: 1273.55, 1277.89, 1282.26, 1286.66 RX: 1295.56, 1300.05, 1304.58, 1309.14 |
Connector | Simplex LC | Simplex LC |
Cable Distance (Max) | 80km | 80km |
Cable Type | SMF | SMF |
Power Consumption | ≤3.3W | ≤3.3W |
Operating Temperature | 0°C to +70°C | 0°C to +70°C |
Form Factor | QSFP28 | QSFP28 |
Transmitter Type | EML | EML |
Receiver Type | PIN | PIN |
Modulation (Electrical) | 4x 25G NRZ | 4x 25G NRZ |
Modulation (Optical) | 4x 25G NRZ | 4x 25G NRZ |
Protocols | QSFP28 MSA, SFF-8636, IEEE 802.3ba 100Gbase-ER4 | QSFP28 MSA, SFF-8636, IEEE 802.3ba 100Gbase-ZR4 |
DDM/DOM | Supported | Supported |
| Pictures | ID# | Description | Price | Stock | Add to Cart |
Q: Can this 80km ZR4 module achieve full distance without using an external optical amplifier over standard SMF? By M***s on 2026-03-06
A: Yes, it is engineered with high-power 1310nm-TX and high-sensitivity 1270nm-RX optics to support up to 80km over standard SMF without inline amplifiers. By admin on 2026-03-07
Q: Does this transceiver support real-time Digital Diagnostic Monitoring (DDM/DOM) for optical power tracking? By M***r on 2025-08-17
A: Yes, DDM/DOM is fully supported. Monitor optical power, laser bias current, module temperature, and supply voltage directly via switch CLI or SNMP. By admin on 2025-08-18
Q: Will this LINK-PP 100G QSFP28 BiDi transceiver work seamlessly on Cisco Nexus switches without third-party optic warnings? By S***z on 2024-12-07
A: Yes! All modules are pre-coded with brand-specific EEPROM compatibility profiles before shipping. Specify your switch brand at checkout for native recognition. By admin on 2024-12-08
Q: What is the operational temperature range, and can it be deployed in unconditioned outdoor cabinets? By S***t on 2024-04-05
A: It supports standard commercial temperatures (0°C to 70°C). For unconditioned outdoor cabinets, ensure proper enclosure ventilation. By admin on 2024-04-05
{{reply_items.topic || reply_items.text}}By {{reply_items.author}}
{{ lpMoneyText(detail_data.displayed_price.unit_prefix, item.displayed_price.value || item.displayed_price.min, detail_data.displayed_price.unit_suffix) }}
Canada
Carrier
CostDelivery TimeTracking
Company
CostTime
{{ shipitem.name }}
{{ isFreeShipping(shipitem)? 'Free Shipping' : lpMoneyText(detail_data.displayed_price.unit_prefix, shipitem.price, detail_data.displayed_price.unit_suffix) }} To Be Negotiated {{shipitem.datemin}}-{{shipitem.datemax}} days Available
{{parseInt(detail_data.left_num) ? detail_data.left_num +' in Stock' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}}