All Products
Services
Support
About Us
Resources
Mind your business with a variety of trusted payment options.
Use order number or tracking number to check shipping status.
Get your quote fast and offer you more professional service.
Help manage your budget & expenditure better.
Free samples support, achieve your test results efficiently.
Professional team support and service, to solve your problems in time.
Ask us whatever you care, we will help you 24/7.
Get your quote fast and offer you more professional service.
Meet us and know our mission, belief, service and more.
Find our locations and get connected with us closely.
Quality management, testing, compatibility and global compliance.
Download ISO, CE, FCC, UL, RoHS and REACH certificates by product line.
Lab tour, optical test bed, compatibility tool and test requests.
Find out the latest news and events around l-p.com
Deep dive into technical guides, industry standards, and SFP compatibility insights.
Detailed product benchmarks and side-by-side comparisons to help you choose the right module.
Explore real-world connectivity solutions for data centers, enterprises, and telecom networks.
Essential tips on choosing data rates, transmission distances, and connector types.
New Customer? Create an account
XBR-SFP10G1590-10 delivers 10Gbps connectivity through its SFP+ CWDM architecture centered on a 1590nm CWDM EML laser and PIN photodiode combination, enabling single-mode fiber links of up to 10km with duplex LC interface and built-in digital diagnostic monitoring that provides live visibility into critical performance metrics including transmit/receive power, bias current, supply voltage, and module temperature.
| Brocade Part Number | XBR-SFP10G1590-10 | Vendor Name | LINK-PP |
| Form Factor | SFP+ | Max Data Rate | 10.7Gbps |
| Wavelength | 1590nm | Max Cable Distance | 10km |
| Connector | Duplex LC | Media | SMF |
| Transmitter Type | EML | Receiver Type | PIN |
| TX Power | -1 to +5dBm | RX Power | -23 to -6dBm |
| Receiver Sensitivity | <-16dBm | DDM Support | Yes |
| Operating Temperature Range | 0 to 70°C | Protocols | SFP+ MSA Compliant, SFF 8472,SFF 8431,802.3ae, ITU-T G.652 |
Brocade XBR-SFP10G1590-10 Compatible LINK-PP module is a commercial 10G SFP+ CWDM transceiver module engineered for 1590nm single-mode fiber links up to 10km with duplex LC connectivity and real-time diagnostics. It delivers CWDM wavelength efficiency, SFP+ hot-pluggable convenience, and SFF-8472-compliant monitoring for metro, enterprise, and data center deployments.
Brocade XBR-SFP10G1590-10 Compatible LINK-PP features a hot-pluggable SFP+ design that allows field replacement without powering down network equipment. Full SFP+ MSA and SFF-8472 compliance ensures interoperability across multi-vendor platforms while enabling comprehensive digital diagnostics.
Operating at 10Gbps, this SFP module meets the bandwidth demands of modern high-capacity backbone and aggregation networks. CWDM wavelength multiplexing allows operators to scale fiber capacity by adding parallel 10G channels without laying new cable.
CWDM technology leverages coarse wavelength spacing to pack multiple 10G channels onto a single fiber pair, dramatically improving fiber utilization. This approach reduces infrastructure costs and simplifies network upgrades for service providers and enterprise IT teams.
The 1590nm transmit wavelength is part of the ITU-T standardized 18-channel CWDM grid optimized for long-haul single-mode transmission. This channel offers excellent fiber optic compatibility and stable operation across commercial temperature ranges.
Engineered for single-mode fiber spans up to 10km, the module maintains adequate optical power budget for reliable metro and campus links. A CWDM EML laser and PIN photodiode combination ensures consistent signal quality throughout the full transmission distance.
The duplex LC connector system provides reliable, low-insertion-loss connections to standard single-mode fiber patch cables and switch ports. Compact LC sizing enables dense port configurations in modern networking equipment and optical distribution frames.
SFF-8472-compliant digital diagnostic monitoring continuously reports temperature, supply voltage, TX/RX power, and laser bias current to the host system. Network operators gain real-time insight into module health for predictive maintenance and rapid fault isolation.
Brocade XBR-SFP10G1590-10 Compatible LINK-PP 10G SFP+ CWDM module is produced under ISO 9001-certified quality systems and meets CE, RoHS, and FCC regulatory requirements for global market deployment.
Each module undergoes rigorous optical and electrical testing, including bit error rate validation, eye diagram analysis, and wavelength verification to ensure consistent performance.
Strict adherence to international safety and environmental standards guarantees consistent build quality and dependable field operation across diverse network environments.
Comprehensive compatibility testing with major switch and router brands ensures seamless plug-and-play operation in diverse network environments.
Brocade XBR-SFP10G1590-10 Compatible LINK-PP CWDM SFP+ modules are subjected to thorough pre-shipment verification to guarantee dependable operation in production networks. Learn more about our quality assurance methodology at the LINK-PP Test Support Center.
Measure exact center wavelength and spectral width to confirm CWDM grid compliance.
Analyze signal quality and jitter performance using high-resolution eye diagram captures.
Run extended BER trials at 10Gbps to detect any transmission errors under load.
Subject modules to hot/cold cycling to verify stable operation in varied environments.
We prioritize secure handling and timely delivery for every Brocade XBR-SFP10G1590-10 Compatible LINK-PP transceiver order. Our coordinated logistics approach ensures smooth dispatch and consistent international reach.
Prevent electrostatic risks with dedicated protective packaging designed for sensitive optics.
Minimize transit damage through robust outer packaging built to withstand handling stresses.
Move purchases quickly from checkout to carrier with efficient internal fulfillment processes.
Deliver to customers worldwide using established shipping routes and trusted carrier networks.
Technicians can install this XBR-SFP10G1590-10 1590nm CWDM transceiver without system downtime - simply insert it into a live SFP+ port and attach standard LC patch cables to establish the optical link. Typical deployments span metro access rings, campus backbone segments, and CWDM mux/demux systems that expand capacity without new cable runs.
LINK-PP offers end-to-end technical support, from pre-sales consultation to post-deployment assistance, ensuring smooth integration and reliable network performance.
Professional guidance to help you select the optimal XBR-SFP10G1590-10 module for your network design and application needs.
Validated compatibility with LINK-PP switches and other mainstream networking platforms for seamless deployment.
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
LINK-PP provides after-sales support for the smooth deployment and reliable operation of the optical modules.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
![]() LS‑DW4010‑40C
| ![]() LS-DW3910-40C
| ![]() LS-DW3810-40C
| ![]() LS-DW3710-40C
| ![]() LS-DW3610-40C
|
|---|
Compatible | Brocade | Brocade | Brocade | Brocade | Brocade | Brocade |
Data Rate (Max) | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps |
Wavelength | 1590nm | 1545.32nm | 1546.12nm | 1546.92nm | 1547.71nm | 1548.51nm |
Connector | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC |
Cable Distance (Max) | 10km | 40km | 40km | 40km | 40km | 40km |
Cable Type | SMF | SMF | SMF | SMF | SMF | SMF |
TX Power | -1 to +5dBm | -1 to +2dBm | -1 to +2dBm | -1 to +2dBm | -1 to +2dBm | -1 to +2dBm |
Receiver Sensitivity | -23 to -6dBm | -15.5dBm | -15.5dBm | -15.5dBm | -15.5dBm | -15.5dBm |
Operating Temperature | 0 to 70°C | 0 to 70°C | 0 to 70°C | 0 to 70°C | 0 to 70°C | 0 to 70°C |
Vendor Name | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP |
Brocade Part Number | XBR-SFP10G1590-10 | 10G-SFPP-ZRD-1545.32 | 10G-SFPP-ZRD-1546.12 | 10G-SFPP-ZRD-1546.92 | 10G-SFPP-ZRD-1547.72 | 10G-SFPP-ZRD-1548.51 |
Temperature | Commercial | Commercial | Commercial | Commercial | Commercial | Commercial |
Form Factor | SFP+ | SFP+ | SFP+ | SFP+ | SFP+ | SFP+ |
Transmitter Type | EML | EML | EML | EML | EML | EML |
Receiver Type | PIN | PIN | PIN | PIN | PIN | PIN |
DDM Support | Yes | |||||
Protocols | SFP+ MSA Compliant, SFF 8472,SFF 8431,802.3ae, ITU-T G.652 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 |
| Pictures | ID# | Description | Price | Stock | Add to Cart |
Q: We want to use this CWDM module in a site where a link failure would be difficult to investigate quickly. Is there a way to make optical issues easier to spot remotely? By T***s on 2026-03-22
A: Yes. Use the DOM feature through a compatible switch or monitoring platform and set alerts for abnormal optical-power or temperature readings. This can help identify fiber loss, connector contamination, or environmental issues before the link drops. By admin on 2026-03-23
Q: We have a 1590nm channel available on our CWDM MUX/DEMUX pair. Do we need to install the same 1590nm 10G CWDM SFP+ module at both ends of the link? By Q***h on 2026-01-25
A: Yes. For a duplex 10G CWDM connection, install one 1590nm CWDM SFP+ module in the network device at each site. Each module connects to the local 1590nm port on the CWDM MUX/DEMUX, while the MUX/DEMUX units carry the signal over the shared single-mode fiber route. Using a different wavelength at either end will prevent the 1590nm channel from linking properly. By admin on 2026-01-26
Q: We are using an eight-channel CWDM MUX rather than a full 18-channel system. Does that automatically mean 1590nm is included? By V***e on 2025-08-25
A: Not always. Eight-channel MUX units can use different wavelength selections, so check the channel labels or datasheet rather than assuming that 1590nm is present. By admin on 2025-08-26
Q: The fiber route between our buildings is relatively short, but it passes through a CWDM MUX and several patch points. Should we still check the optical loss budget? By R***r on 2025-04-04
A: Yes. Even on a short route, CWDM MUX insertion loss, patch-panel loss, dirty connectors, and splice loss can affect the received signal. Verify that the total loss stays within the module’s supported optical budget. By admin on 2025-04-05
{{reply_items.topic || reply_items.text}}By {{reply_items.author}}
{{ lpMoneyText(detail_data.displayed_price.unit_prefix, item.displayed_price.value || item.displayed_price.min, detail_data.displayed_price.unit_suffix) }}
Canada
Carrier
CostDelivery TimeTracking
Company
CostTime
{{ shipitem.name }}
{{ isFreeShipping(shipitem)? 'Free Shipping' : lpMoneyText(detail_data.displayed_price.unit_prefix, shipitem.price, detail_data.displayed_price.unit_suffix) }} To Be Negotiated {{shipitem.datemin}}-{{shipitem.datemax}} days Available
{{parseInt(detail_data.left_num) ? detail_data.left_num +' in Stock' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}}