All Products
Services
Support
About Us
Resources
Mind your business with a variety of trusted payment options.
Use order number or tracking number to check shipping status.
Get your quote fast and offer you more professional service.
Help manage your budget & expenditure better.
Free samples support, achieve your test results efficiently.
Professional team support and service, to solve your problems in time.
Ask us whatever you care, we will help you 24/7.
Get your quote fast and offer you more professional service.
Meet us and know our mission, belief, service and more.
Find our locations and get connected with us closely.
Quality management, testing, compatibility and global compliance.
Download ISO, CE, FCC, UL, RoHS and REACH certificates by product line.
Lab tour, optical test bed, compatibility tool and test requests.
Find out the latest news and events around l-p.com
Deep dive into technical guides, industry standards, and SFP compatibility insights.
Detailed product benchmarks and side-by-side comparisons to help you choose the right module.
Explore real-world connectivity solutions for data centers, enterprises, and telecom networks.
Essential tips on choosing data rates, transmission distances, and connector types.
New Customer? Create an account
DWDM-SFP10G-53.33-40-I is a 10G SFP+ DWDM transceiver operating on the 1553.32nm (C30) wavelength, built with duplex LC interfaces for 40km single-mode transmission and equipped with real-time Digital Optical Monitoring (DOM) to withstand hostile temperatures ranging from -40°C to +85°C.
| H3C Part Number | DWDM-SFP10G-53.33-40-I | Vendor Name | LINK-PP |
| Form Factor | SFP+ | Max Data Rate | 10.7Gbps |
| Wavelength | 1553.32nm | Max Cable Distance | 40km |
| Connector | Duplex LC | Media | SMF |
| Transmitter Type | EML | Receiver Type | PIN |
| TX Power | -1 to +2dBm | RX Power | -16 to -1dBm |
| Receiver Sensitivity | -15.5dBm | DOM Support | Yes |
| Operating Temperature Range | -40 to 85°C | Protocols | SFP+ MSA Compliant, CPRI, eCPRI |
H3C DWDM-SFP10G-53.33-40-I Compatible LINK-PP combines C30-channel DWDM precision with an extended 40km optical reach to maximize single-mode fiber utilization. Built with a duplex LC interface and integrated telemetry diagnostics, it maintains continuous signal integrity across severe industrial thermal swings. This architecture provides a robust, manageable backbone solution for capacity-constrained optical links.
Built on a hot-pluggable SFP+ footprint, this module enables quick field installation without interrupting active system operations. It utilizes a cooled EML laser alongside a high-sensitivity PIN photodiode to ensure accurate signal generation and reception over long links. This design ensures exceptional optical stability while maintaining low overall power consumption.
Delivering a full 10Gbps line rate, this transceiver expands bandwidth capability for traffic-heavy routing and switching equipment. It provides clear, low-latency links across enterprise networks and metro aggregation site deployments. Its compact SFP+ form factor maximizes port density on high-capacity line cards.
By leveraging Dense Wavelength Division Multiplexing (DWDM), the transceiver allows multiple data streams to travel simultaneously over a single fiber pair. This capability dramatically boosts bandwidth density without requiring expensive new fiber installation. It provides an efficient path for scaling network capacity over existing optical cabling.
Operating precisely on the ITU-T C30 channel at 1553.32nm, the module guarantees tight spectral stability required for dense optical networks. This exact channel assignment prevents adjacent channel crosstalk and simplifies optical routing. It integrates smoothly into standard 100GHz ITU grid DWDM multiplexers and demultiplexers.
Designed for extended-reach connections, the transceiver maintains strong signal integrity across single-mode fiber (SMF) distances up to 40km. Its optical budget compensates for attenuation over long spans without needing intermediate optical amplifiers. This makes it an ideal fit for campus backbones and inter-facility links.
Featuring an industry-standard duplex LC connector, the module establishes secure optical connections with low insertion loss. The precise mechanical alignment ensures high return loss performance and clean light transmission across the physical mating surface. It mates seamlessly with standard single-mode patch cables.
Integrated Digital Optical Monitoring (DOM) gives network administrators live access to key operational metrics via a standard 2-wire interface. System software can monitor real-time temperature, laser bias current, optical output power, and received optical power. This proactive telemetry helps prevent unexpected link downtime and speeds up troubleshooting.
H3C DWDM-SFP10G-53.33-40-I Compatible LINK-PP module is manufactured under an ISO 9001 certified quality system and complies with CE, RoHS, and FCC standards to ensure maximum operational safety and environmental responsibility.
Each module completes comprehensive optical bit-error-rate and thermal endurance testing prior to shipping to verify stable field performance.
These global compliance marks validate that the hardware meets strict electromagnetic interference and environmental protection requirements.
Comprehensive EEPROM profiling and real-hardware validation ensure instant plug-and-play operation with major enterprise switches and routers.
Every DWDM-SFP10G-53.33-40-I 10G DWDM SFP+ module undergoes strict physical and optical verification to guarantee faultless field operation. Discover our complete validation methodology at the LINK-PP Test Support Center.
Verify precise wavelength accuracy and channel spacing performance.
Evaluate optical signal clarity and transmitter waveform quality.
Measure data transmission accuracy across full line speeds.
Ensure stable hardware operation under severe thermal conditions.
We package and dispatch each transceiver securely to ensure fast, reliable delivery. Every order arrives safely worldwide.
Protect sensitive optical circuits against static discharge during handling.
Shield the delicate module from physical impact during transit.
Process your orders quickly to ensure prompt fulfillment schedules.
Ship products directly to your locations through global carriers.
H3C DWDM-SFP10G-53.33-40-I Compatible LINK-PP module installs effortlessly via its hot-pluggable SFP+ interface and standard LC connectors for immediate deployment. Designed for harsh industrial environments, it enables high-capacity 10G long-reach connections across campus backbones, metro DWDM transport networks, and remote cellular fronthaul aggregations.
LINK-PP offers end-to-end technical support, from pre-sales consultation to post-deployment assistance, ensuring smooth integration and reliable network performance.
Professional guidance to help you select the optimal DWDM-SFP10G-53.33-40-I module for your network design and application needs.
Validated compatibility with LINK-PP switches and other mainstream networking platforms for seamless deployment.
Comprehensive step-by-step guidance for installation, configuration, and initial setup, ensuring accurate deployment and reliable, stable operation from the start.
Ongoing technical support throughout the product lifecycle, delivering long-term stability for enterprise and carrier-grade networks.
LINK-PP provides after-sales support for the smooth deployment and reliable operation of the optical modules.
15-day no-reason return and refund
Free replacement for dead-on-arrival (DOA) or defective items within the initial period
Free repair services for manufacturing defects throughout the warranty period
Warranty exclusions and conditions apply
![]() LS-DW3010-40C
| ![]() LS‑DW5510‑40C
| ![]() LS‑DW5410‑40C
| ![]() LS‑DW5310‑40C
| ![]() LS‑DW5210‑40C
|
|---|
Compatible | H3C | H3C | H3C | H3C | H3C | H3C |
Data Rate (Max) | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps | 10.7Gbps |
Wavelength | 1553.32nm | 1553.32nm | 1533.46nm | 1534.25nm | 1535.04nm | 1535.82nm |
Connector | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC | Duplex LC |
Cable Distance (Max) | 40km | 40km | 40km | 40km | 40km | 40km |
Cable Type | SMF | SMF | SMF | SMF | SMF | SMF |
TX Power | -1 to +2dBm | -1 to +2dBm | -1 to +2dBm | -1 to +2dBm | -1 to +2dBm | -1 to +2dBm |
Receiver Sensitivity | -15.5dBm | -15.5dBm | -15.5dBm | -15.5dBm | -15.5dBm | -15.5dBm |
Operating Temperature | -40 to 85°C | 0 to 70°C | 0°C to +70°C | 0°C to +70°C | 0°C to +70°C | 0°C to +70°C |
Vendor Name | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP | LINK-PP |
H3C Part Number | DWDM-SFP10G-53.33-40-I | DWDM-SFP10G-53.33-40 | DWDM-SFP10G-33.47-40 | DWDM-SFP10G-34.25-40 | DWDM-SFP10G-35.04-40 | DWDM-SFP10G-35.82-40 |
Temperature | Industrial | Commercial | Commercial | Commercial | Commercial | Commercial |
Form Factor | SFP+ | SFP+ | SFP+ | SFP+ | SFP+ | SFP+ |
Transmitter Type | EML | EML | EML | EML | EML | EML |
Receiver Type | PIN | PIN | PIN | PIN | PIN | PIN |
DOM Support | Yes | |||||
Protocols | SFP+ MSA Compliant, CPRI, eCPRI | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 | SFP+ MSA, CPRI, eCPRI, SFF-8472, SFF-8431 |
| Pictures | ID# | Description | Price | Stock | Add to Cart |
Q: How do we monitor internal thermal levels and voltage performance while the module is deployed at a remote site? By N***y on 2026-03-12
A: The integrated real-time digital diagnostic monitoring (DDM) lets you read live temperature, supply voltage, laser bias current, and optical power via your switch CLI. By admin on 2026-03-13
Q: Can I use this optical transceiver for a 10GBASE-ZR or 10GBASE-ZW Ethernet deployment? By Z***s on 2025-10-25
A: Yes, the LS-DW3010-40I module is fully compatible with both 10GBASE-ZR (10.3125Gbps) and 10GBASE-ZW (9.953Gbps) protocol standards. By admin on 2025-10-26
Q: We are connecting passive 100GHz DWDM multiplexers. Does this optic align with Channel 30? By J***n on 2025-04-04
A: Yes, it operates strictly on the 100GHz ITU C-band grid at C30 (1553.32nm) for seamless Mux/Demux channel matching. By admin on 2025-04-05
{{reply_items.topic || reply_items.text}}By {{reply_items.author}}
{{ lpMoneyText(detail_data.displayed_price.unit_prefix, item.displayed_price.value || item.displayed_price.min, detail_data.displayed_price.unit_suffix) }}
Australia
Carrier
CostDelivery TimeTracking
Company
CostTime
{{ shipitem.name }}
{{ isFreeShipping(shipitem)? 'Free Shipping' : lpMoneyText(detail_data.displayed_price.unit_prefix, shipitem.price, detail_data.displayed_price.unit_suffix) }} To Be Negotiated {{shipitem.datemin}}-{{shipitem.datemax}} days Available
{{parseInt(detail_data.left_num) ? detail_data.left_num +' in Stock' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}}