Free shipping: CA$ 140.58+ (transceivers & cages), CA$ 852.00+ (other products). For larger quantities or custom pricing, contact us directly.
Need Help?
Chat live with us
Live Chat
Want to call?

+ 86-752-3386717

Canada · English · CAD
Shop by filter Compatible P/N shop — brand, category & attributes in one table Open shop
  • Mind your business with a variety of trusted payment options.

  • Use order number or tracking number to check shipping status.

  • Get your quote fast and offer you more professional service.

  • Help manage your budget & expenditure better.

  • Deep dive into technical guides, industry standards, and SFP compatibility insights.

  • Detailed product benchmarks and side-by-side comparisons to help you choose the right module.

  • Explore real-world connectivity solutions for data centers, enterprises, and telecom networks.

  • Essential tips on choosing data rates, transmission distances, and connector types.

Select Currency
USD - US Dollar
EUR - Euro
GBP - British Pound
CAD - Canadian Dollar
AUD - Australian Dollar
JPY - Japanese Yen
SEK - Swedish Krona
NOK - Norwegian Krone
IDR - Indonesia Rupiahs
BRL - Brazilian Real
THB - Thailand Baht

OSFP 400G LR4 vs. QSFP112 LR4: Which Is Right for You?

Reviews & Comparisons November 27, 2026
LINK-PP-Limer

OSFP 400G LR4 vs. QSFP112 LR4: Which Is Right for You

OSFP 400G LR4 and QSFP112 LR4 can provide similar 400G optical connectivity, but they use different host electrical interfaces and module form factors. The right choice depends on your switch or network adapter, so matching the transceiver to the host port is more important than comparing optical specifications alone.

Both module types use a four-channel optical architecture for 400G Ethernet transmission over single-mode fiber. However, their electrical lane configurations, mechanical structures, and host-device requirements are different. These differences affect module installation, equipment compatibility, and network upgrade planning.

For network operators and equipment integrators, understanding where the two transceivers are similar and where they differ makes it easier to select a suitable 400G LR4 solution without unnecessary changes to the existing hardware.


Shared Optical Specifications of OSFP 400G LR4 and QSFP112 LR4

Despite their different host-side designs, OSFP 400G LR4 and QSFP112 LR4 can share the same optical transmission architecture. Their optical similarities mainly involve four-lane signal transmission, CWDM4 Technology, and single-mode fiber connectivity.

Shared Optical Specifications of OSFP 400G LR4 and QSFP112 LR4

Four-Lane Optical Architecture for 400G LR4

Both module types use four optical lanes to deliver 400G data connectivity. Each lane carries a 100G-class PAM4 optical signal, and the four channels work together to support the required 400G Ethernet connection.

PAM4 stands for Pulse Amplitude Modulation with four signal levels. Unlike NRZ modulation, which uses two signal levels to represent one bit per symbol, PAM4 uses four levels to represent two bits per symbol. This allows more information to be transmitted within each signal cycle.

For a 400G LR4 optical interface, the four optical channels operate together to provide the required aggregate bandwidth. Each channel carries a 100G-class data stream, and the module handles the conversion between electrical signals from the host and optical signals sent through the fiber.

The 400G-LR4-10 specification defines the optical transmission requirements, including the four transmit channels, four receive channels, and wavelength multiplexing functions. It does not prescribe one specific host electrical lane arrangement or module form factor.

This distinction is important when comparing OSFP and QSFP112. Their optical transmission architecture can remain similar even though the electrical signals entering the modules follow different lane configurations.

CWDM4 Technology for Wavelength Multiplexing

CWDM4 Technology allows four optical channels to share the same fiber path by assigning a different wavelength to each channel. Instead of requiring four separate fiber pairs, the module combines these wavelengths into one optical connection for each transmission direction.

The four nominal wavelengths used in the 400G LR4 optical configuration are:

  • 1271nm
  • 1291nm
  • 1311nm
  • 1331nm

Each wavelength carries its own data channel. At the transmitting end, the optical multiplexer combines the four wavelength channels into a single outgoing optical signal. At the receiving end, the demultiplexer separates the combined signal into four individual channels.

This process allows four optical channels to travel through one fiber strand in the same direction. A second strand carries the signals in the opposite direction, forming a bidirectional connection.

The main advantage is more efficient use of the available fiber infrastructure. A four-channel optical connection can provide 400G capacity without requiring four independent fiber pairs.

Single-Mode Fiber Connectivity and Transmission Reach

Both module types use single-mode fiber (SMF) for optical transmission over distances of up to 10km. This makes them suitable for connecting network equipment across data center facilities, campus networks, and other locations requiring longer 400G links.

Single-mode fiber provides a narrow optical transmission path that supports longer distances than typical multimode fiber applications. Its characteristics make it suitable for the 400G LR4 optical interface, where the four wavelength channels travel through the same fiber pair.

A duplex LC connector provides two separate optical paths:

  • Transmit (TX): Sends optical signals from one network device to the other.
  • Receive (RX): Receives optical signals from the remote device.

One fiber carries the outgoing signal, while the other carries the incoming signal. When connecting the two endpoints, ensure the TX and RX paths are correctly aligned to establish a bidirectional optical link.

The 10km reach also gives network planners more flexibility when connecting equipment located in different racks, rooms, or buildings. However, the actual achievable distance depends on the complete optical link budget, including transmitter output, receiver sensitivity, fiber attenuation, and connector losses.

These shared optical characteristics allow OSFP and QSFP112 modules to support similar 400G LR4 fiber connections, even though their host-side interfaces and physical designs are different.


Host Interface Architecture in OSFP 400G LR4 and QSFP112 LR4

The main difference between these two 400G transceiver types lies in their host-side electrical interfaces. The OSFP configuration uses eight 50G-class PAM4 electrical lanes, while the QSFP112 configuration uses four 100G-class PAM4 electrical lanes to connect with the host device.

Their host-side data paths differ even when the optical transmission architecture is similar. This affects how the host PCB, module connector, and transceiver signal-processing circuitry are designed.

Understanding the difference between these electrical interfaces helps explain why two modules with similar optical specifications cannot automatically replace each other.

8×50G PAM4 Electrical Lanes in OSFP

The OSFP 400G LR4 configuration uses an 8×50G PAM4 electrical interface. It receives data through eight electrical lanes from the host device, with each lane carrying a nominal 50G data stream.

The actual signaling rate is 53.125Gbps per lane. This includes the additional signaling capacity required by the encoding used in the 400G Ethernet architecture.

Its main electrical interface characteristics include:

  • Electrical Interface: 8×50G PAM4
  • Electrical Lane Rate: 53.125Gbps per lane
  • Number of Electrical Lanes: 8
  • Host Interface Standard: 400GAUI-8

The eight electrical lanes provide the host-side connection to the transceiver. Inside the module, the electrical signals are processed and mapped into four higher-rate optical channels for transmission.

This arrangement is useful for equipment designed around an eight-lane electrical interface. The host can distribute the 400G connection across eight electrical signal paths rather than requiring four 100G-class paths.

For equipment manufacturers, this lane arrangement affects the host connector pin assignment, PCB signal routing, and high-speed electrical design. The host must provide the correct number of lanes and meet the corresponding signal-integrity requirements.

An OSFP module should therefore be selected when the equipment supports its specified electrical interface, not simply because the device has an available 400G port.

4×100G PAM4 Electrical Lanes in QSFP112

Unlike the eight-lane arrangement, the QSFP112 400G LR4 configuration uses a 4×100G PAM4 electrical interface. Each of its four electrical lanes carries a 100G-class data stream from the host device.

Its main electrical interface characteristics include:

  • Electrical Interface: 4×100G PAM4
  • Electrical Lane Rate: 106.25Gbps per lane
  • Number of Electrical Lanes: 4
  • Host Interface Standard: 400GAUI-4

Each electrical lane operates at a higher signaling rate than an individual lane in the OSFP configuration. The module processes these four electrical signals and maps them to its four optical channels.

This arrangement reduces the number of electrical lanes required for the host connection. However, fewer lanes do not automatically mean that the overall system is easier to design. Each lane must support a higher signaling rate, which places different requirements on the host PCB, connector, and electrical channel.

QSFP112 is designed around this four-lane architecture. It is therefore suitable for network platforms that provide the corresponding 400GAUI-4 electrical interface.

When selecting this module, check both the QSFP112 port type and the supported electrical lane configuration. A device with a different 400G electrical interface may not support the module simply because its port also carries a 400G designation.

400GAUI-8 and 400GAUI-4 Interface Differences

400GAUI-8 and 400GAUI-4 are two electrical interface specifications used for 400G connections between a host device and a pluggable transceiver. The numbers indicate the number of electrical lanes, while the lane rates describe how much data each lane carries.

Comparison 400GAUI-8 400GAUI-4
Electrical Lanes 8 4
Nominal Lane Rate 50G 100G
Actual Lane Rate 53.125Gbps 106.25Gbps
Modulation PAM4 PAM4
Aggregate Signaling Rate 425Gbps 425Gbps
Corresponding Form Factor in This Comparison OSFP QSFP112

Both interfaces use PAM4 modulation, where each signal symbol represents two bits of information. This allows each electrical lane to carry more data than an NRZ-based interface at a comparable symbol rate.

The main difference is how the total bandwidth is distributed. The eight-lane interface uses more electrical lanes at a lower rate per lane, while the four-lane interface carries the same aggregate signaling rate through fewer lanes at a higher rate.

It is also useful to distinguish the 400G Ethernet data rate from the 425Gbps aggregate signaling rate. The latter reflects the encoded signaling capacity across the electrical lanes. It does not mean that the Ethernet application delivers 425Gbps of user data.

For equipment designers and network operators, this distinction matters when checking interface specifications. A transceiver must match the electrical interface provided by the host platform rather than relying on its 400G optical rating alone.


OSFP 400G LR4 and QSFP112 LR4 Form Factor and Port Design

Although these two module types can share similar optical specifications, they have different mechanical designs. Each uses a dedicated module outline, host cage, and connector assembly, so the two form factors cannot be directly interchanged.

These mechanical differences affect more than the external shape of the transceiver. They also influence the host PCB layout, front-panel port arrangement, connector placement, and module installation process.

For equipment designers and network operators, understanding these differences is important when selecting transceivers for existing switches or planning new 400G hardware.

OSFP 400G LR4 and QSFP112 LR4 Form Factor and Port Design

OSFP Module Dimensions and Host Cage

The OSFP form factor uses a dedicated mechanical design defined by the OSFP MSA specification. Its module outline, insertion structure, and cage dimensions are designed to work together as a standardized hardware interface.

The host cage provides the opening and mechanical support for the transceiver. It also contains the corresponding connector that mates with the module's electrical contacts when the module is fully inserted.

Several design elements define this form factor:

  • Module Dimensions: The OSFP module follows a specified mechanical outline to ensure a consistent fit within compatible host equipment.
  • Host Cage: The cage provides the matching opening, positioning features, and retention structure.
  • Module Connector: The contact interface is designed to mate with the corresponding OSFP host connector.
  • PCB Footprint: The cage and connector assembly must follow the specified mounting and positioning requirements on the host board.

The cage is not simply an opening in the equipment front panel. It is a mechanical assembly that helps maintain the correct position between the module, connector, and host PCB.

During equipment development, the OSFP MSA provides dimensional references and mechanical requirements for the module and host-side components. These details help manufacturers maintain consistent module fit across different equipment designs.

For an existing switch, the important point is that the host must have a properly designed OSFP port. A different 400G cage cannot be used as a direct replacement without changing the corresponding mechanical and electrical interface.

QSFP112 Module Dimensions and Host Cage

QSFP112 uses a different mechanical package from OSFP, with its own module dimensions, cage structure, and host connector requirements. Although it belongs to the wider QSFP family, its electrical contact design supports 112G-class signaling.

The QSFP112 MSA defines the mechanical outline of the module and the corresponding host cage and connector assembly. The module also includes a retention mechanism that holds it in place after insertion.

Its main mechanical features include:

  • Module Dimensions: A standardized QSFP112 outline that fits the corresponding host port.
  • Host Cage: A dedicated cage assembly designed around the QSFP112 module profile.
  • Module Connector: An updated contact arrangement designed for high-speed electrical signaling.
  • PCB Footprint: A matching host-board layout that supports the required connector and cage positioning.

The QSFP112 connector and cage must work together to maintain accurate electrical contact when the module is installed. Their mechanical arrangement also helps ensure that the module is correctly positioned within the host port.

For equipment manufacturers, following the QSFP112 MSA is important when designing the front panel and PCB interface. Even a small difference in the mechanical outline or connector position can affect module insertion and electrical mating.

These features allow QSFP112 modules to be installed in compatible switches and network adapters designed for this form factor. However, a QSFP112 module cannot be treated as a physically compatible replacement for an OSFP module.

Physical Installation and Mechanical Compatibility

The difference between these two form factors becomes clear during installation. An OSFP transceiver is designed for an OSFP cage, while a QSFP112 transceiver requires a corresponding QSFP112 cage and connector assembly.

The two modules have different physical outlines and mating structures. Therefore, they cannot be inserted directly into each other's host ports, even when their optical specifications are similar.

Installation Requirement OSFP 400G LR4 QSFP112 LR4
Module Form Factor OSFP QSFP112
Compatible Host Cage OSFP Cage QSFP112 Cage
Host Connector OSFP-specific QSFP112-specific
PCB Layout OSFP MSA design QSFP112 MSA design
Direct Physical Interchangeability No No

For network equipment already in service, this means a module replacement must follow the original port design. Installing a QSFP112 transceiver in an OSFP port is not possible through a simple adapter or software configuration.

When designing a new switch or network adapter, the choice also affects the front-panel arrangement. The equipment manufacturer must select the appropriate cage and connector system before finalizing the PCB and enclosure layout.

Before ordering a replacement or adding a new 400G connection, check the module type specified for the equipment. The host cage, connector assembly, and mechanical outline must match the selected transceiver.

Matching the physical form factor is the first step toward proper installation. Electrical interface support and module recognition should then be verified separately.


Device Compatibility Checks for OSFP 400G LR4 and QSFP112 LR4

Choosing between OSFP 400G LR4 and QSFP112 LR4 requires checking whether the target switch or network adapter supports the selected module. Although both can provide similar 400G optical connectivity, their host interfaces and device requirements are different.

Compatibility involves more than the physical port. The host must support the module's electrical interface, recognize its identification information, and communicate with its management functions. Checking these requirements before ordering helps reduce installation problems and unexpected link failures.

Switch and NIC Transceiver Support

Both OSFP and QSFP112 transceivers require compatible host interfaces and optical application support. An OSFP module needs a host port supporting 400GAUI-8, while a QSFP112 module requires a corresponding 400GAUI-4 interface. Both host platforms must also support the intended 400G-LR4-10 optical application.

A device may provide 400G ports, but this does not automatically mean that every 400G optical module is supported. Equipment manufacturers may specify particular form factors, electrical interfaces, and validated transceiver models for each platform.

Before selecting a module, check the following details:

  • Port Configuration: Confirm whether the equipment provides OSFP or QSFP112 ports.
  • Electrical Interface: Verify support for 400GAUI-8 or 400GAUI-4, depending on the selected module.
  • Optical Application Support: Check whether the platform supports the required 400G-LR4-10 transmission specification.
  • Supported Transceiver List: Review the manufacturer's compatibility list for approved or validated module options.
  • Network Protocol: Confirm support for the intended application, such as 400GbE.

The exact device model and hardware revision are important because compatibility can vary between product families. Two switches from the same manufacturer may use different port configurations or software policies.

For network upgrades, also check whether the existing firmware supports the intended transceiver. This helps avoid situations where a physically compatible module is rejected during system initialization.

Vendor Coding and Module Recognition

Vendor coding is another important consideration when selecting OSFP or QSFP112 transceivers, particularly when using third-party optical modules. It refers to the identification information programmed into a module's memory, including its manufacturer name, part number, and other product details.

When a transceiver is inserted, the host device reads this information through its management interface. The equipment uses the module data to identify its type and determine which supported functions and configurations are available.

Some equipment platforms accept compatible third-party modules, while others may apply vendor-specific restrictions or require approved identification information. These policies can affect both OSFP and QSFP112 transceivers, regardless of their optical specifications.

Before ordering, consider these points:

  • Vendor Identification: Confirm that the module's coding is suitable for the target equipment.
  • Part Number Recognition: Check whether the device recognizes the programmed module information.
  • Third-Party Support: Verify whether the equipment accepts compatible modules from other suppliers.
  • Host Software Requirements: Review any vendor-specific restrictions in the device documentation.

Vendor coding does not change the module's optical specifications or physical form factor. It helps align the module's identification information with the host device's recognition requirements.

For larger deployments, testing sample modules in the actual equipment is a practical way to confirm recognition before ordering the full quantity. This also allows the network team to check whether the host reports the correct module information.

CMIS Implementation and Firmware Compatibility

CMIS (Common Management Interface Specification) defines how a host device communicates with and manages supported optical modules. It provides a standardized management framework for functions such as module identification, configuration, and diagnostic monitoring.

Through the management interface, a host can access module information and supported functions. Depending on the implementation, this may include module status, temperature readings, voltage information, optical transmit power, and receive power.

Both OSFP and QSFP112 modules may use CMIS-based management, but supporting CMIS does not automatically guarantee compatibility between every module and host platform. Different devices and modules may implement different CMIS versions, application features, and management functions.

Firmware also plays a role in module recognition and initialization. The host software must be able to communicate with the transceiver and handle its supported management functions correctly.

Before deployment, check the following:

  • CMIS Version: Confirm that the host supports the management specification and features implemented by the module.
  • Application Support: Verify that the required module operating mode is recognized by the equipment.
  • Firmware Version: Check whether the switch or network adapter firmware supports the selected transceiver.
  • Management Functions: Confirm that module identification and diagnostic information can be accessed correctly.
  • Initialization Status: Check whether the module completes the host's startup and configuration process.

A module may be physically installed and recognized by the host but still fail to establish a working link if its application settings or initialization sequence are not supported.

For this reason, compatibility testing should cover more than whether the equipment detects the transceiver. It should also include module initialization, link establishment, and access to the expected management information.

These checks help determine whether an OSFP or QSFP112 transceiver can operate correctly with the intended equipment. Host-to-module compatibility should be verified separately from optical interoperability between the two link endpoints.


Optical Interoperability Between OSFP 400G LR4 and QSFP112 LR4

OSFP and QSFP112 transceivers can communicate with each other over a fiber link when both support compatible 400G-LR4-10 optical specifications. Their different form factors do not prevent optical interoperability because the optical interface can remain the same even when the host-side electrical interfaces differ.

For example, one network device can use an OSFP module while the other uses a QSFP112 module. This arrangement is possible when both modules meet the required optical specifications and their respective host devices support the selected configurations.

Optical Interoperability Between OSFP 400G LR4 and QSFP112 LR4

Optical Compatibility Across Different Form Factors

Optical interoperability depends on the optical interface rather than the physical shape of the transceiver. This means two modules can use different form factors while following the same optical transmission specification.

The 400G-LR4-10 specification from the 100G Lambda MSA defines a four-channel CWDM optical interface for 400G Ethernet applications. It specifies the optical transmission characteristics but does not restrict the transceiver to a specific electrical interface or module form factor.

This allows compatible implementations to use different host-side configurations. The electrical lane arrangement can vary while the optical link follows the same 400G-LR4-10 requirements.

As a result, an OSFP module and a QSFP112 module can establish an optical connection when both implement compatible optical specifications. However, sharing the LR4 designation alone does not guarantee interoperability.

When evaluating two modules, compare their actual specifications rather than relying only on their product names. Important details include:

  • The applicable optical application and specification.
  • The transmitter and receiver operating characteristics.
  • The optical lane rate and modulation format.
  • The maximum supported transmission distance.
  • The connector type and fiber requirements.

These details help determine whether the two modules are designed for the same optical link.

It is also important to distinguish optical interoperability from host compatibility. An OSFP module may communicate optically with a QSFP112 module, but each must still be installed in a host port designed for its own form factor and electrical interface.

Fiber Link Setup Between OSFP and QSFP112

Once both modules are installed in their respective host ports, the fiber connection must provide the correct transmit-to-receive paths.

Use a compatible duplex single-mode fiber cable and check its condition, polarity, and optical loss. The link budget must remain within the operating limits of both transceivers.

A link budget describes the available optical power margin between the transmitter and receiver. It considers transmitter output power, fiber attenuation, connector losses, and other losses along the optical path.

For a 10km connection, the total optical loss must remain within the specified operating range. Excessive connector loss, damaged fiber, or poor-quality patch connections can reduce the received optical power and affect link performance.

Before connecting the two endpoints, check the following:

  • Use a compatible duplex single-mode fiber cable.
  • Confirm that the fiber length is within the supported transmission distance.
  • Inspect the connectors and fiber ends for contamination or damage.
  • Follow the correct TX/RX polarity at both endpoints.
  • Verify that the optical power levels meet the module specifications.

Correct fiber polarity is essential for establishing the connection. A reversed TX/RX arrangement can prevent the two endpoints from receiving each other's optical signals.

If the link does not come up after installation, check the fiber polarity and optical power readings before assuming that the transceiver is incompatible.

FEC Requirements for End-to-End Connectivity

Forward Error Correction (FEC) is an important requirement for reliable 400GBASE-R communication. It helps detect and correct certain transmission errors through additional coding information.

For a 400GbE link using 400GBASE-R, the host PCS handles RS(544,514) FEC encoding and decoding. The transceiver converts electrical and optical signals, while the host system manages the corresponding PCS and FEC functions.

This distinction matters when connecting two different module types. Even when the optical specifications match, the host devices must still support the required PCS and FEC operation.

When troubleshooting a 400G LR4 connection, consider the following:

  • FEC Support: Confirm that both host platforms support the required FEC mode.
  • FEC Configuration: Check that the settings are correctly configured at both endpoints.
  • PCS Compatibility: Verify that the host interfaces use compatible 400G Ethernet configurations.
  • Link Status: Check whether the host reports successful link establishment and stable operation.
  • Error Monitoring: Review available counters to identify persistent errors after the connection is established.

A link may fail to establish if the host-side configurations are incompatible, even when the optical modules and fiber connection are suitable.

Optical interoperability is therefore possible between different module form factors, but it depends on matching optical specifications and compatible host-side configurations. Each module must still be installed in its own supported equipment interface.


Selecting OSFP 400G LR4 or QSFP112 LR4 for Your Equipment

The right 400G LR4 transceiver depends primarily on the host interface and form factor supported by your network equipment. OSFP is the appropriate choice for compatible OSFP ports, while QSFP112 is designed for equipment with matching QSFP112 interfaces.

Both options can provide similar 400G optical connectivity over 10km of single-mode fiber. The key is to select a module that matches the host port, electrical interface, and device compatibility requirements.

Before making a selection, identify the existing host interface and confirm whether the equipment uses an eight-lane or four-lane electrical configuration. This helps narrow down the suitable module type before comparing individual product specifications.

When to Choose OSFP 400G LR4

Choose an OSFP transceiver when your switch or network adapter provides an OSFP port and supports the corresponding 400GAUI-8 electrical interface.

This configuration uses eight 50G-class PAM4 electrical lanes to connect with the host device. It is suitable for equipment designed around the OSFP form factor and its eight-lane electrical architecture.

LINK-PP LO-CW400-LR4C is one option for this type of deployment. It combines an OSFP package with a 400G-LR4-10 optical interface for transmission over up to 10km of single-mode fiber.

Its main specifications include:

  • Form Factor: OSFP
  • Host Interface: 8×50G PAM4 (400GAUI-8)
  • Maximum Ethernet Data Rate: 400Gbps
  • Transmission Distance: Up to 10km
  • Optical Interface: 4×100G PAM4

For network equipment with compatible OSFP ports, this model provides an option for 400G LR4 connectivity.

When evaluating this module, check whether the host supports the OSFP mechanical interface and the corresponding eight-lane electrical configuration. Also confirm the required vendor coding and firmware support before deployment.

When to Choose QSFP112 LR4

Choose a QSFP112 transceiver when your network equipment uses a QSFP112 port and supports the corresponding 400GAUI-4 electrical interface.

Unlike the eight-lane OSFP configuration, this design uses four 100G-class PAM4 electrical lanes. It connects to host platforms designed to provide four high-speed electrical lanes for a 400G connection.

LINK-PP LQ-CW400-LR4C is designed for this type of host interface. It combines a QSFP112 package with a 400G-LR4-10 optical interface for transmission distances of up to 10km over single-mode fiber.

Its main specifications include:

  • Form Factor: QSFP112
  • Host Interface: 4×100G PAM4 (400GAUI-4)
  • Maximum Ethernet Data Rate: 400Gbps
  • Transmission Distance: Up to 10km
  • Optical Interface: 4×100G PAM4

For equipment built around the QSFP112 form factor, this model offers a matching 400G optical solution without requiring an OSFP host interface.

When selecting this option, verify that the equipment supports QSFP112 rather than assuming that any QSFP-family port will accept the module. Check the host documentation for the supported module generation, electrical interface, and compatibility requirements.

LINK-PP 400G LR4 Options for Different Host Interfaces

LINK-PP offers both OSFP and QSFP112 400G LR4 transceivers for different host interface designs. Although their optical specifications are similar, their electrical interfaces and module packages are designed for different equipment platforms.

The two models provide the following choices:

Product Model Form Factor Host Interface Electrical Lanes
LO-CW400-LR4C OSFP 400GAUI-8 8×50G PAM4
LQ-CW400-LR4C QSFP112 400GAUI-4 4×100G PAM4

The selection should start with the equipment interface rather than the product price or module appearance. If the host uses an OSFP port, choose the corresponding OSFP implementation. If it uses a QSFP112 port, select a module designed for that form factor.

Before placing an order, confirm the following information:

  • Equipment Model: Identify the exact switch, router, or network adapter model.
  • Host Port Type: Confirm whether the port uses OSFP or QSFP112.
  • Electrical Interface: Check support for 400GAUI-8 or 400GAUI-4.
  • Optical Application: Verify that the equipment supports 400G-LR4-10.
  • Module Recognition: Confirm the required vendor coding and software compatibility.
  • Link Requirements: Check the fiber type, distance, and FEC configuration.

For larger deployments, testing a sample module in the target equipment is a practical way to confirm compatibility before purchasing the full quantity. This also gives the network team an opportunity to check link establishment and diagnostic functions.

If you are unsure which version fits your equipment, contact us with your switch or network adapter model for assistance with module selection.


Final Checks Before Choosing OSFP 400G LR4 or QSFP112 LR4

Final Checks Before Choosing OSFP 400G LR4 or QSFP112 LR4

OSFP 400G LR4 and QSFP112 LR4 offer similar optical transmission capabilities, but their host interfaces and physical designs are different. The OSFP version uses an 8×50G PAM4 electrical interface, while the QSFP112 version uses a 4×100G PAM4 interface.

Neither option is universally better. The right choice depends on the form factor, electrical interface, and compatibility requirements of your switch or network adapter. Checking these details before ordering helps avoid module mismatches and simplifies 400G network deployment.

LINK-PP offers both OSFP and QSFP112 400G LR4 transceivers for different host platforms. Visit the LINK-PP Official Store to explore available optical modules or contact the team for product selection assistance.

Next: Select → Buy

Stay on the guide for specs—use these exits when you are ready to shortlist parts.

  1. Browse this category

    Open 400G QSFP-DD/OSFP/QSFP112 to filter by the specs that match your BOM.

    Browse 400G QSFP-DD/OSFP/QSFP112
  2. Request a quote

    Send part numbers or OEM codes if you want a quote—no obligation.

    Request a quote